Descargar Imprimir esta página

Garland AMAZON 650 XE-V20 Manual De Instrucciones página 24

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 1
English
minimum section is 1.5 mm
metres, always unrolled and adequate for outdoor
use. The use of the cable extension adequate for
outdoor use, reduces the risk of electric shock.
Place the cable extension in such a way that it does
not touch the water and that it will not fall into the
water when the pump starts working. The cable
extension must always be well away from the water
and dry.
All electrical connexions should be outside of the
water, at a safe distance from the pump and water
conducts and protected from possible humidity.
Connect the pump to the mains. The machine should
work.
6.3. CHECKING POINTS AFTER START UP
Check that water comes out the impulsion hose
after a few seconds, that the noise of the machine is
normal and that it does not vibrate. If you detect any
anomaly, stop the machine immediately, check the
hose installation and the connexions to the mains.
If necessary, take the machine to your nearest after
sales dealer for repair.
Never carry on using the machine.
This pump comes with a self pumping system. When
the pump is submerged and started, this system
expels all the air through the ventilation orifice. If the
water level is below this orifice, some water might also
come out through the orifice. This is normal.
6.4. RECOMMENDATIONS
Do not use this pump with mud, sandy water,
excessively dirty and murky water or water with high
levels of impurities and/or filaments. These elements
could cause the blockage of the pump as well as
2
and no longer than 25
24/88
wearing the machine a lot quicker.
The pump will lower its water outflow the higher the
impulsion hose is. Always try and lower as much as
possible. Check the graph of outflow/height in point
4.3.
Do not leave the pump in the workplace after finishing
your task as it could get stuck in the mud once the
water has been cleared.
Do not block the water exit. The pump must be placed
in such a way that water can outflow correctly.
If the bottom is very dirty, place a platform such as a
brick and place the pump on top thus reducing the
quantity of impurities that the pump will absorb.
7. MAINTENANCE AND SERVICE
The removal of the security elements, a poor
maintenance or the substitution of spares and
accessories by non original ones can all cause severe
corporal damages.
Always carry out all the maintenance work
with the machine unplugged from the
mains.
Unplug the machine always before carrying
out any work on the pump. Read the
instruction manual before carrying out any
maintenance work.
7.1. MAINTENANCE AFTER WORK
Carry out the following maintenance work once
you finish your task to guarantee that the machine
functions correctly next time.

Publicidad

loading