was (nearly) fully charged and increases to 8 hours in case of
a deeply discharged battery.
3.
RECONDITION
Optional reconditioning for deeply discharged lead-acid
batteries.
Reconditioning is applicable to the charge algorithms
NORMAL and HIGH and can be selected with the App on your
smartphone.
When in RECONDITION mode the battery will be charged with
low current up to a higher voltage at the end of the absorption
phase.
During reconditioning the maximum current is equal to 8% of the
nominal current until the maximum voltage is reached.
Reconditioning is terminated after one hour or when the maximum
voltage is reached, whichever comes first. See table.
Example:
For a 12/7 charger: the recondition current is
7 x 0.08 = 0.56A
4.
FLOAT
Keeps the battery at constant voltage and fully charged.
5.
STORAGE
Keeps the battery at reduced constant voltage to limit gassing and
corrosion of the positive plates.
Slow self-discharge is prevented by an automatic weekly refresh of
the battery with a short absorption charge.
3.2 Lithium-ion (LiFePO₄) batteries
When charging a Lithium-ion battery, the Blue Smart IP67 Charger uses
a specific charging algorithm for Lithium-ion batteries, to ensure optimum
performance. Select LI-ION with the app on your smart phone.

3.3 When a load is connected to the battery

A load can be applied to the battery while charging, as long as the
current draw is much lower than the rated output of the battery charger.
Reconditioning is not possible when a load is connected to the battery.