GFCI/RCD-Protected
Receptacle
Supply Stop
1. Install an Electrical Outlet
WARNING: Risk of electric shock, fire, or personal injury.
This product must be grounded and connected only to a
dedicated, nominal 120 VAC, 60 Hz circuit protected by a
minimum 15 Amp Ground-Fault Circuit-Interrupter (GFCI) or
Residual Current Device (RCD).
CAUTION: Risk of property damage. A single extension cord
may be used provided that the cord type begins with "SJ", is
12-gauge, grounded (12/3), not longer than 25 feet (7.6 meters),
and plugged into a GFCI* electrical outlet. Promptly replace
any extension cord that exhibits any sign of damage.
NOTE: Follow local codes when determining the electrical outlet
location.
Install a 120 V GFCI- or RCD-protected electrical outlet within 32"
(813 mm) of the toilet to accommodate the length of the power
cord.
Do not plug in the seat until instructed to do so.