Descargar Imprimir esta página

EXFO FPM-300 Guia Del Usuario página 35

Publicidad

9 Especificaciones técnicas
Las siguientes especificaciones técnicas pueden cambiar sin previo
aviso. La información contenida en esta sección se proporciona
únicamente como referencia. Si desea obtener las especificaciones
técnicas más recientes del producto, visite la página web de EXFO en
www.exfo.com.
a
SPECIFICATIONS
b
Model
Power meter port
Power range
c
(dBm)
Range displayed (dBm)
Number of calibrated wavelengths
Power uncertainty
e
Resolution (dB)
Automatic offset nulling
h
i
Warmup time
(s)
Display units
Automatic wavelength recognition
Screen refresh rate (Hz)
Tone detection (Hz)
Battery life (hours) (typical)
Warranty and recommended
calibration interval (years)
GENERAL SPECIFICATIONS
Size (H x W x D)
Weight
Temperature
operating
storage
Relative humidity
a
SPECIFICATIONS
b
Model
Central wavelength (nm)
c
Spectral width
(nm)
Output power (dBm)
d
Power stability
(dB)
8 hours
e
Battery life
(hours)
Enables automatic wavelength recognition
Tone generation (Hz)
Warranty and recommended calibration interval (years)
GENERAL SPECIFICATIONS
Size (H x W x D)
Weight
Temperature
operating
storage
Relative humidity
NOTES
a. Guaranteed unless otherwise specified.
b. All specifications valid at 23 °C ± 1 °C, with an FC connector.
c. rms for lasers and —3 dB width for LEDs; typical values for LEDs.
FPM-300/FLS-300/FOT-300
I
FPM-302
Ge
10 to –60
Down to –65
d
10
± 5 % ± 1 nW
0.01
f
Yes
0
dB/dBm/W
j
Yes
3
270, 1 k, 2 k
> 300
3
18.5 cm x 10.0 cm x 5.5 cm
0.4 kg
–10 °C to 50 °C
–40 °C to 70 °C
0 % to 95 % non-condensing
23BL
1310 ± 20
1550 ± 20
5
1/ 1
±0.10
120
Yes
270, 1 k, 2 k
3
18.5 cm x 10.0 cm x 5.5 cm
0.4 kg
–10 °C to 50 °C
40 °C to 70 °C
0 % to 95 % non-condensing
MPORTANTE
FPM-302X
GeX
26 to –50
Down to –50
10
± 5 % ± 10 nW
0.01
g
Yes
0
dB/dBm/W
Yes
3
270, 1 k, 2 k
> 300
3
(7
1
/
in x 4 in x 2
1
/
in)
4
8
(0.9 lb)
(14 °F to 122 °F)
(–40 °F to 158 °F)
234BL
235BL
1310 ± 20
1310 ± 20
1550 ± 20
1490 ± 10
1625 ± 15
1550 ± 20
5
5
1/ –3/ –5
1/ –4.5/ –3
±0.10
±0.10
100
120
Yes
Yes
270, 1 k, 2 k
270, 1 k, 2 k
3
3
1
(7
/
in x 4 in x 2
4
(0.9 lb)
(14 °F to 122 °F)
(–40 °F to 158 °F)
d. After 15 minutes warmup; expressed as ± half the difference between the maximum and
minimum values measured during the period, with an APC connector on the power meter.
e. Typical autonomy in Auto mode.
f. EA-EUI only available on models 23BL and 235BL.
NOTES
a. Guaranteed unless otherwise specified.
b. All specifications valid at 1550 nm and 23 °C ± 1 °C,
with an FC connector.
c. In CW mode; sensitivity defined as 6 x rms noise level.
d. Wavelengths: 830 nm, 850 nm, 980 nm, 1300 nm, 1310 nm, 1450
nm, 1490 nm, 1550 nm, 1590 nm and 1625 nm.
e. Traceable to NIST; FPM-302X: up to 20 dBm.
f. From 10 dBm to –50 dBm.
g. From 26 dBm to –35 dBm.
h. Power of > –40 dBm for FPM-302, and of > –25 dBm
for FPM-302X.
i. For ± 0.05 dB and temperatures of > 18 °C.
j. At 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm
and 1625 nm; power of > –50 dBm for FPM-302,
and of > –40 dBm (typical) for FPM-302X.
12D
850 ± 25
1300 +50/–10
50/135
–20/ –20 (62.5/125 μm)
±0.10
120
Yes
270, 1 k, 2 k
3
1
/
in)
8
01-VCL
850 +10/
20
1
–3 (50/125 μm)
±0.25
250
Yes
270, 1 k, 2 k
3
30

Publicidad

loading

Este manual también es adecuado para:

Fls-300Fot-300