Low battery indication
Important:
Replace the batteries
immediately when the red low battery LED
comes on (see page 3). Follow instructions
under section titled "BATTERY INSTALLA-
TION" on page 3.
Audio alarm mute
To silence the audio alarm,
press the MUTE button. Press
the MUTE button again to
restore the audio alarm.
Sensor failure mode
If the sensor is not working correctly, the
AccuProbe Leak Detector will not come out of
the warm-up mode. (Some competitive units
without this function will not alert you that the
sensor is malfunctioning or has failed.)
If the AccuProbe detector does not come out
of warm-up, first be sure the sensor is plugged
in all the way. If that does not correct the situa-
tion, replace the sensor.
Unscrew tip to
replace filter
Figure 2
6
(AccuProbe
UV)
Push straight on (do not twist) to install sensor
Filter
Pull straight out (do not twist) to remove sensor
Maintenance
Batteries:
Replace the batteries when the
red low battery LED turns on. See "BATTERY
INSTALLATION" on page 3.
Sensor filter replacement:
sensor tip as shown to replace the filter. For
optimum performance, replace filter whenever
it becomes visibly dirty with grease or oil or
every 2-3 months (depending on use).
Note: Never clean dirty filters with a solvent
or soap and water. Always replace with a
new filter supplied with the leak detector or
they can be re-ordered from your supplier
or distributor.
Sensor replacement:
pulling out of socket. Install the new sensor by
aligning the notch in the sensor cover with the
raised keyway on the sensor socket holder (see
Figure 2).
Note: Do not force sensor into socket.
Misalignment can damage the sensor pins.
Unscrew the
Remove sensor by
Keyway alignment