Warning
• This Comelit product was designed for use in the creation of audio and video communication systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Cut off the power supply before carrying out any maintenance procedures.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in
the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems,
by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
•
The module cannot be considered as part of a fire detection system. Incoming pre-alarm, alarm, evacuation and fault notifications on
internal units and switchboards are additional information and do not replace fire alarm system alerts.
Module for integration of the IP (ViP) video entry system
with VMS software. The module will monitor the ViP and
forward information to the connected VMS software.
The available information is as follows:
•
connection status of ViP devices to the network;
•
ViP call started;
•
ViP call in progress;
•
ViP call failed
•
ViP call forwarded
Supported VMS: Wisenet SSM from Hanwha Techwin
DESCRIPTION Fig. 1 (page 2)
1. ViP system Ethernet port (AUTO IP)
2. Dip-switch to perform the "Reboot with predetermined
network settings" and "Restore factory settings"
procedure.
3. Power supply input via 1441, 1441B.
4. CV1 and CV2 for setting port A2 (Fig. 2)
5. CV3 and CV4 for setting port A3 (Fig. 2)
6. A4 NO POE Ethernet Port for VMS connection
(default: "Static IP address" 192.168.1.200, netmask
255.255.255.0).
7. A3 "POE" Ethernet port, can be set as NO POE
(default: "Static IP address" 192.168.1.200, netmask
255.255.255.0).
8. A2 "POE" Ethernet port, can be set as NO POE
(default: "Static IP address" 192.168.1.200, netmask
255.255.255.0).
9. A1 "POE" Ethernet port (default: "Static IP address"
192.168.1.200, netmask 255.255.255.0).
MAIN FEATURES
Compatible system
DIN rail mounting
DIN modules (no.)
Power supply voltage
Min./max. absorption
Operating temperature
Operating relative humidity
IP protection rating
CONFIGURATION
This operation requires a PC loaded with the ViP Manager
software, version 2.10 or later.
The ViP Manager software is available to download free of
charge from the website pro.comelitgroup.com
6
RESTORE DEFAULT NETWORK SETTINGS
This procedure allows the module to restart with the
default network parameters.
If the module is restarted again:
•
the parameters for the previous configuration will be
restored if no changes were made by the user;
•
if parameters have been changed using ViP
Manager, the module will start up with the new
network parameters.
√ DIP in OFF position
1. Cut off the device power supply
2. Set DIP1 to ON
3. Restore the device power supply
4. Wait for approximately 20-40 sec., until the
LEDs flash slowly and alternately (1 sec. red
/ 1 sec. green)
5. Set DIP1 back to OFF
» The green LED will flash for 5 seconds
» The device will start up with the default
» The next time the device is restarted, the
RESTORE FACTORY PARAMETERS
This procedure is used to restore the factory settings for
all parameters.
√ DIP in default position (OFF)
ViP
1. Cut off the device power supply
Yes
2. Set all the DIP-switches to ON
4
48
56 Vdc
÷
3. Restore the device power supply
50 mA
4. Wait for approximately 20-40 sec., until the
+5
+40°C
÷
LEDs flash rapidly and alternately (0.1 red /
25
75%
÷
0.1 green)
IP30
5. Reset all the DIP-switches to OFF
» The red LED will flash for 5 sec.
» The device will restore all parameters to
network settings applied
saved parameters will be restored
the factory settings and restart as normal
OFF
1
2
OFF
1
2
OFF
1
2
OFF
1
2
1 2
OFF
1
2