EN: Installation Sheet
Enrolling
To enroll the sensor, set your panel into program mode. Then
go to the Learn Sensors menu. Refer to your specific alarm
panel manual for details on these menus. Insert the battery.
Close the case (you will hear a click when the case latches are
engaging and disengaging). Then select the appropriate
sensor group and number.
Mounting
One side of the sensor is marked with an arrow poiting up; this
indicates the location of the reed switch. The magnet should be
mounted facing this side of the sensor. Please check the table
about distances to define the maximum distance in each
direction.
Included with this device is double sided tape for the contact
and the magnet. Choose a suitable location for the sensor by
following the procedure in the section "Testing the Sensor"
ensuring desired signal strength is achieved. For reliable
bonding, ensure the surface is clean and dry. Apply the tape to
the sensor and then to the desired location. Apply firm
pressure for several seconds.
Note:
When mounting with double sided tape, ensure
temperatures are above 10°C and will remain above 10°C for
at least 24 hours to ensure proper bond. After 24 hours, the
bond will hold at lower temperatures.
For security approved installations the contact back plate shall
be screwed to the mounting surface. Any removal from the
surface will activate the tamper.
An additional small screw is supplied in case you want to lock
the sensor cover to its base. Please check country specific
security standards whether this might be required.
You can also use the contact back plate that shall be screwed
to the mounting surface. Any removal from the surface will
activate the back tamper.
Where possible, install sensors within 30 m of the panel. While
a transmitter may have an open-air range of 150 m or more,
the environment at the installation site may have a significant
effect on operational range. Changing a sensor location may
improve wireless communication.
Testing the Sensor (Test Weekly)
The sensor test verifies proper communication between the
sensor and the panel/receiver. To test the sensor, refer to the
specific panel/receiver documentation and do the following:
1.
Put the panel/receiver into sensor test mode.
2.
Open the door/window the sensor is protecting. The
sensor transmits a signal.
3.
Listen for siren beeps to determine the appropriate
response.
4.
Exit sensor test mode.
2 / 16
Installing/Replacing the Battery
WARNING:
Lithium battery inside!
Risk of burned skin, blindness, or death. Risk of
explosion or disabled safeguard if the battery is
replaced by an incorrect type, subjected to
extremely low air pressure, or used with another
equipment. Disposal into fire or a hot oven,
heating above 100°C, mechanically crushing or
cutting, disassembling, recharging, short
circuiting, or exposing the battery to water can
result in an explosion.
When the battery is low a signal will be sent to the control
panel. To install/replace the battery:
1.
Slide the top cover to disengage it from the sensor, then
remove to reveal the battery.
2.
Install/replace with a CR2032 battery ensuring the + side
of the battery faces towards you.
3.
Re-attach the cover. Ensure the Top (as marked on the
inside of the cover) points away from the battery. You
should hear a click when the cover engages properly.
Note:
Removing the cover will trigger a zone tamper signal to
the control panel.
Models
•
RF-1110-07-1:
mini DWS LoNa, white
•
RF-1110-07-3:
mini DWS LoNa, mahogany
Specifications
Compatibility
Wireless operating frequency
Power output
Battery
Quiescent current
Maximum current
Low voltage fault
Battery Life
Magnet Gap
Operating environment
Temperature
Relative humidity
Distances
Mounted on non-ferromagnetic material:
Approach distance X (switch closed)
Removal distance X (switch open)
Approach distance Z (switch closed)
Removal distance Z (switch open)
Approach distance Y (switch closed)
Removal distance Y (switch open)
Minimum recommended installation distances are:
Approach distance X
Approach distance Z
Approach distance Y
Aritech LoNa transceivers (for
example, ZeroWire)
433.65 MHz
−2 dBm EIRP
3 V lithium (PANASONIC CR2032)
1.4 µA
15 mA
2.2 V
5 to 8 years
15.5 mm maximum
0 to +49°C
5 to 95% noncondensing
15 mm
17 mm
19 mm
23 mm
23 mm
27 mm
10 mm
12 mm
16 mm
P/N 466-5446 • REV D • ISS 11DEC20