F. Set Up(Weekly Setting)
- Press this button to enter Weekly Setting mode, 5 modes.
- Working time is preset in the program, users just need to follow the instruction below.
1) Press once, unit would work at 1000W from 06:20~10:20, on Saturday and Sunday
2) Press twice, unit would work at 2000W from 17:45~21:45,on Monday to Friday
3) Press three time, unit would work at 1000W from 16:30~20:30, on Saturday and Sunday
4) Press four times, unit would work at 2000W from 22:00~05:00, on Monday to Sunday
5) Press five times, Weekly Setting function would be turned off. Displayer show 00
Note:
5) When heater is on, then "Start-up" Time setting is invalid, while "Cut-off" Time setting is valid.
6) When there is conflict on "Timed Time" and the Cut-off time under "Weekly Setting" mode, the unit
would be turned off as per the time whichever occurs earlier.
7) When the Adaptive Start temperature is set lower than that temperature set under "Weekly Setting"
mode and/or detected room temperature, the heater would not be turned on.
TROUBLE SHOOTING
Problem
Fireplace NOT start
Fireplace Auto Shut-
off
Remoter NOT work
Flame Freezing
No Heat
EN
only applicable on Remoter
Possible Causes
Kettle Lead
Connector not well
connected
Adaptive Start-Up /
Weekly Timer work
Low Battery Volume
Distance exceed
signal receiver range
Gearing Wheel Loose
Room temperature
is higher than set
value
16
What to Do
Check the Kettle Lead Connect
and Plug, make sure that there
is power supply.
Check your setting, if you had
set room temperature or On/
off time.
Replace battery, 2*AAA
Walk close to the fireplace
and try the remoter directly in
front of the fireplace
take off the lower cover of the
fireplace, and adjust tightness
of the gear.
Check your setting