Unit description
3
This document describes the Ford Connected Charge
Station. You can find the exact device details on the type
label of the Ford Connected Charge Station.
Electrical
Ford Connected Charge
Station characteristics
48A
Nominal current (A)
(configurable
connected load
values)
240 V (Line-to-Line voltage) /
Line voltage (VAC)
208 V
(nominal)
Grid frequency (Hz)
60 Hz
(nominal)
Overvoltage category III
I
Protection class
Integrated power
Accuracy +/- 5%
meter
Connections
Mounted on-wall, or in-wall
Cable feed
Charging cable
2x 6 AWG (L1/L2) 1x 8 AWG (GND)
wire specifications
for the charging cable only
(observe local codes/regulations)
Charging cable with Type 1
Charging cable
coupler according to SAE J1772
(including coupler)
Cable length 20 ft / approximately
6 m
Output voltage (V
240 V and 208 V
AC)
Maximum charging
11.5 kW
capacity (kW)
Power input cable L1 / L2 / PE
Maximum mains
cross- section up to 2 AWG (35
terminal wire size
mm²)
capability
Communication
& features
Ford Connected Charge Station Installation Manual
Electrical
Ford Connected Charge
Station characteristics
SAE J1772
Vehicle–charger
Communication
Protocol (CP)
Bluetooth (BLE 4.2) – Setup App
Authentication
Display
9 RGB-LEDs
Wi-Fi 802.11n – 150 Mbit/s
Network interfaces
Authentication and
Bluetooth (BLE 4.2) - Setup-App
mobile
communications
OCPP
Version 1.6
Mechanical data
10.2 x 17.7 x 5.5
Dimensions (W × H ×
Inches 258 x 450 x
D)
141 mm
17.53 lbs
Weight (including
wall mount bracket &
7.95 kg
charging cable)
Minimally 35 inches above floor
Installation height
level (to the bottom of the device)
Minimally 900 mm above floor
level (to the bottom of the device)
IP protection class
NEMA Type 3S
Protection against
ANSI/UL2594:2016
mechanical impact
Ambient conditions
Operating
-40°F to +122°F
temperature range
-40°C to +50°C
-40°F to +185°F
Storage temperature
range (°C)
-40°C to +85°C
Max. 9,842 ft above sea level
Altitude (m)
Max. 3,000 m above sea level
Certification
compatibility
ANSI/UL2594:2016 / CAN/CSA
Other standards and
C22.2 No. 280-16
guidelines
SKLJ98-10C823-CA
Electrical
Ford Connected Charge
Station characteristics
ANSI/UL2231-1:2021 / CAN/CSA
C22.2 No. 281.1-21
ANSI/UL2231-2:2020 / CAN/CSA
C22.2 No. 281.2-20
FCC Part 15, Subpart B / ICES003
FCC Part 15, Subpart C / RSS.2010
/ RSS-GEN
NEC Article 625 compliant
Ford OCPP (Open Charge Point
Tested with OCPP
Protocol) backend
backend(s)
NOTICE
A shutdown, or a reduction in charging current, may
occur to prevent the charge station overheating. This
is a safety feature.
3.1
In the box
Scope of delivery for the Ford Connected Charge
Station. See Fig. 19 on the inside of the back cover.
A
Main unit
Design cover
B
C
Charging cable with coupler
D
Blind plugs
Wall mount bracket
E
F
Dock rear holder, dock front cover & dock insert
G
Screw (5 x 12 mm)
Screw (4 x 16 mm)
H
I
Cable fixation. See Fig. 10.
J
Screws (4 x 13 mm). See Fig. 10.
K
T6 Torx bit
See also Required tools.
3.2
Wireless interface connections
3.2.1
Bluetooth
The Bluetooth connection is used to set up the Wi-Fi AP
(access point) when starting up the charge station. Note
that the charge station cannot be controlled via Bluetooth.
US
3

Publicidad

loading

Este manual también es adecuado para:

Lj98-10c823-ac