INSTALLATION INSTRUCTION
Position your completed mantel close to its final location. Make sure you can access the back of the
mantel as your electric fireplace appliance will be installed from back.
Using a Phillips head screwdriver, remove the screws and the metal mounting center opening. Next
unpack the electric fireplace appliance carefully. Position the appliance behind the fireplace with front
facing the wood mantel. With the help of an adult assistant, lift the appliance and gently slide it into the
opening in the mantel. Make sure the appliance is centered left and right in the opening. Be careful
when placing appliance and adjusting, bottom of appliance could scratch the finish of the base/hearth
of your fireplace. Re-attach the mounting brackets with the Phillips head screwdriver, and supplied
screws.
DO NOT OVER TIGHTEN. With the help of an
assistant, carefully lift completed unit and place it
with the front facing out in the final location you
have chosen for your fireplace. Make sure to
secure the electrical cord before lifting or moving
completed fireplace. When choosing a final loca-
tion, make sure you will have clear access to
grounded electrical outlet.
GROUNDING INSTRUCTIONS:
This heater is for use on 120 volts. The cord has
a plug as shown at (A) in figure 2. An adapter as
shown at (C) is available for connecting
three-blade grounding-type plugs to two-slot
receptacles. The green grounding lug extending
from the adapter must be connected to a perma-
nent ground such as a properly grounded outlet
box. The adapter should not be used if a
three-slot grounded receptacle is available.
NOTE: Adapters are NOT for use in Canada
ELECTRICAL SPECIFICATIONS
Voltage: 120VAC 60Hz
Watts: 1400 Watts
≥1"
≥1"
(A)
Grounding Pin
Cover of Grounded Outlet Box
Adapter
Grounding Lug
Metal Screw
Cover of Grounded Outlet Box
03
≥1.5"
ELECTRIC
FIREPLACE
INSERT
≥1"
≥1"
(B)
REAR VIEW OF FIREPLACE
Figure 2