To Replace Regulator
1. Release all air pressure from air tank. See "To
Drain Tank" in the Maintenance section.
2. Unplug outfit.
3. Remove the regulator ring and remove the con-
sole cover.
Regulator
Ring
4. Using an adjustable wrench loosen pressure relief
tube nut at air tank and pressure switch.
5. Using an adjustable wrench, rotate the pressure
switch assembly as shown.
Regulator
Outlet
Pressure
Gauge
Before you store the air compressor, make sure you
do the following:
1. Review the "Maintenance" section on the preced-
ing pages and perform scheduled maintenance as
necessary.
2. Set the On/Auto/Off lever to "OFF".
3. Turn the regulator counterclockwise and set the
outlet pressure to zero.
4. Remove the air tool or accessory.
5. Pull ring on safety valve allowing air to bleed from
the tank until tank pressure is approximately 20
psi. Release safety valve ring.
6. Drain water from air tank by opening drain valve
on bottom of tank.
Cover
Tank
Pressure
Gauge
Quick
Connect
STORAGE
15 - ENG
6. Remove the outlet pressure gauge, tank pressure
gauge, and quick connect (if equipped) from the
regulator.
7. Remove the regulator.
8. Apply pipe sealant tape to the nipple.
9. Assemble the regulator and orient as shown.
NOTE: Arrow indicates flow
of air. Make sure it is point-
ing in the direction of air
flow.
10. Reapply pipe sealant to
outlet pressure gauge,
tank pressure gauge,
and quick connect.
11. Reassemble outlet pressure gauge,tank pressure
gauge, and quick connect. Orient outlet pressure
gauge and tank pressure gauge to read correctly.
Tighten quick connect with wrench.
12. Rotate pressure switch assemble into correct
position.
13. Replace console cover and regulator ring.
water will corrode and weaken the air tank
causing a risk of air tank rupture.
7. After the water has been drained, close the drain
or drain valve.
NOTE: If drain valve is plugged, release all air pres-
sure. The valve can then be removed, cleaned, then
reinstalled.
8. Protect the electrical cord and air hose from dam-
age (such as being stepped on or run over). Wind
them loosely around the compressor handle. (If so
equipped)
Store the air compressor in a clean and dry location.
Regulator
Arrow
Water will condense in the
air tank. If not drained,
D24305