3. Operation
■
Manual vane angle (Wireless remote controller)
Fig. 3-1
Fig. 3-2
Fig. 3-3
Display
Setting
Step 1
Display
Setting
Step 5
No setting
* The draft reduction can be set for only 1 vane.
The setting is enabled only for the last vane that was set.
3.6. 3D i-See sensor setting
3.6.1 3D i-See sensor setting
Main
Main menu
Operation
ON
RETURN SELECT
MENU
OFF
HOLD
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
ON
RETURN SELECT
MENU
OFF
HOLD
12
1 Going to the Manual vane setting
mode
Press the
button.
(Start this operation from the
status of remote controller
display turned off.)
"FUNCTION" is lighted and "1"
blinks. (Fig. 3-1)
Press the
button to select "2",
and then press the
2 Selecting the vane number (Fig.
3-2)
Press the
buttons to select
the vane number A, and then
A
press the
button.
3 Setting the vane angle (Fig. 3-3)
Press the
buttons to select
the vane angle B.
Point the wireless remote
B
controller toward the receiver on
the indoor unit, and then press
the
button.
4 Press the
button to
complete the settings.
Step 2
Step 3
Step 4
No display
Draft reduction*
1 Select "Operation" from the Main
menu, and press the [SELECT/
HOLD] button.
2 Select "Comfort" from the
Operation menu, and press the
[SELECT/HOLD] button.
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
RETURN SELECT
MENU
button.
HOLD
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display: SELECT
Cursor
RETURN SELECT
MENU
HOLD
3.6.2 Air distribution
Air distribution
M-NET address
Identify unit Check button
Input display: SELECT
Address
RETURN SELECT
MENU
HOLD
Air distribution
M-NET address
Auto vane
Direct/Indirect
Direct/Indirect setting
Select: SELECT
Cur.
RETURN SELECT
MENU
HOLD
Cooling
Heating
3 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
ON
OFF
4 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT/HOLD] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
ON
according to whether persons are
OFF
detected in the room by the 3D
i-See sensor.
• Seasonal airflow
When the thermostat turns off,
the fan and the vanes operate
according to the control settings.
1 Select the M-NET address for the
units to whose vanes are to be
fixed, with the [F2] or [F3] button,
and press the [SELECT/HOLD]
button.
Press the [F4] button to confirm the
Check
unit.
The vane of only the target indoor
unit is pointing downward.
ON
OFF
2 Select the menu with the [F4]
button.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the same
as during normal operation.
During cooling mode, all of the
vanes move to the horizontal
airflow direction.
During heating mode, all of the
ON
OFF
vanes move to the down airflow
direction.
Area: The vanes move to the
down airflow direction toward
areas with a high floor temperature
during cooling mode and toward
areas with a low floor temperature
during heating mode. Otherwise,
the vanes move to the horizontal
airflow direction.
Direct/Indirect: The vanes
automatically move relative to
the areas where persons are
detected.
The vanes operate as indicated
in the following table.
Vane setting
Direct
horizontal → swing
keep horizontal
keep downward
downward → horizontal
Indirect