Descargar Imprimir esta página

Paslode CF150-PP Manual De Funcionamiento página 19

Clavadora inalámbrica

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting
Normal Stage of Operation
SYMPTOM
Tool operates properly, but fasteners do not
drive fully.
Tool operates properly, but fasteners are
sometimes over-driven, and sometimes
under-driven.
Tool operates, but no fastener is driven.
Tool operates erratically or appears to be
losing power - tool indicator light is green.
Tool operated and drove fasteners, but
driver blade did not return to up position.
Combustion chamber does not drop after
tool cycles.
18
POSSIBLE PROBLEMS
Nail Hole Locating Probe requires adjustment.
Fuel cell is low.
There may be loss of seal in combustion
chamber.
Nail Hole Locating Probe is not adjusted
properly for the type of material being fastened.
Wrong fasteners being used.
Follower not properly engaged behind fastener
strip.
Jammed fastener.
Fuel cell is low or too cold.
Spark plug wire is loose.
Air filter is dirty, causing tool to overheat.
Tool is dirty.
Built-up dirt and debris on driver blade or in
nose bore.
Tool is dirty.
Nail Hole Locating Probe is bent, or is dirty.
Still not working? Here are more options:
Your nailer may qualify for our Cordless 2 Year
Service Promise. Visit paslode.com for more
information or call us at 1-800-222-6990.
Keep your cordless nailer in top form. Visit paslode.com
and watch our Cleaning and Maintenance videos.
19
SERVICE
Adjust the Probe.
Check fuel cell and replace as required.
Press Nail Hole Locating Probe against
workpiece for one minute. Pull trigger. If
fastener does not drive, there is a leak that
requires service.
Adjust the Probe. Readjust
as required when material density or thick-
ness of material being fastened changes.
Use only fasteners meeting Paslode
specifications. Check Fasteners and Ap-
plications section for fastener types and
sizes recommended for use in Paslode
Cordless tool.
Position follower behind fastener strip and
engage strip.
Clear jam.
Check fuel cell.
Check spark plug wire.
Remove air filter and clean. Use soap and
water to remove stubborn debris.
Clean tool.
Clean driver blade and nose bore with
degreaser cleaner.
Clean tool.
Clean track or replace the Probe.
®

Publicidad

loading

Este manual también es adecuado para:

906200