• Once installed, the appliance must not be tilted at an angle
GB
greater than 5° and it is necessary to wait 2h before connect-
ing it to the power supply to switch it on. The same applies if
the appliance is moved afterwards.
• If the appliance has been switched off or disconnected from
the power supply, it is necessary to wait 5 minutes until
switching on again.
• Do not make any additional openings on the appliance. Do not
install any gadgets in the appliance.
• Do not attempt to climb up to the top of the appliance.
Intended use
• This appliance is intended to be used for commercial applica-
tions, for example in kitchens of restaurants, canteens, hos-
pital and in commercial enterprises such as bakeries, butch-
eries, etc., but not for continuous mass production of food.
• The appliance is designed to keep food or beverages, under
cool state and to display them for retail sale. Any other use
may lead to damage to the appliance or personal injury.
• Operating the appliance for any other purpose shall be
deemed a misuse of the device. The user shall be solely liable
for improper use of the device.
Grounding installation
This appliance is classified as protection class I and must be
connected to a protective ground. Grounding reduces the risk of
electric shock by providing an escape wire for the electric current.
This appliance is fitted with a power cord with grounding plug
or electrical connections with grounding wire. The connections
must be properly installed and grounded.
Main parts of the product
(Fig.1 on page 3)
1:
Glass door
2:
Adjustable rack
3:
Air suction
4:
Air outlet
Remark: The content of this manual applies for all listed items
unless specified otherwise. The appearance may vary from the
shown illustrations.
Control panel
(Fig.2 on page 3)
5:
Refrigerant LED indicator
6:
Defrost LED indicator
7:
Up
8:
Down
9:
Light ON/ OFF
10: SET
Circuit diagram
(Fig.3 on page 4)
DP: Defrost probe
TP: Thermostat probe
DTC: Digital Temperature Controller
D:
Display panel
M:
Fan Motor
L:
Lamp
OP: Over Load Protector
C:
Compressor
8
Preparation before use
• Remove all protective packaging and wrapping.
• Check that the device is in good condition and with all ac-
cessories. In case of incomplete or damaged delivery, please
contact the supplier immediately. In this case, do not use the
device.
• Clean the accessories and the appliance before use (See ==>
Cleaning & Maintenance).
• Make sure the appliance is completely dry.
• Place the appliance on a horizontal, stable and heat resistant
surface that is safe against water splashes.
• Keep the packaging if you intend to store your appliance in
the future.
• Keep the user manual for future reference.
NOTE! Due to manufacturing residues, the appliance may emit
a light odor during the first few uses. This is normal and does
not indicate any defect or hazard. Make sure the appliance is
well ventilated.
Operating instructions
(Fig.2 on page 3)
• Connect the power plug with a suitable electrical outlet. Leav-
ing the appliance for running some hours to reach the cooling
temperature before placing the beverage or food inside the
appliance.
1). Setting the temperature
• Press SET to enter into the setting mode. The set tempera-
ture is displayed.
• Press Up or Down to increase or decrease the set temper-
ature.
• Press SET again to confirm the setting and exit. Then, inside
cabinet temperature is displayed.
Note:
• If no button is pressed within 10 seconds. The newly set tem-
perature will be stored.
• The temperature setting range from 0°C to 6°C. The actual
temperature inside the appliance can be affected by the am-
bient temperature.
• Keep the door open time as short as possible in order to keep
a cool temperature inside.
2). Illumination inside the cabinet
• Press Light ON/ OFF to switch ON the light. Press Light ON/
OFF again to switch OFF the light.
3). Refrigerant LED indicator
• During the cooling operation (compressor enabled), this re-
frigerant LED indicator will lights up constantly.
• After the inside cabinet reach the set temperature, the refrig-
erant LED indicator will flashes continuously.
• When defrost start, the refrigerant LED indicator light off.
4). Defrost LED indicator
• During the defrost operation, this defrost LED indicator will
lights up constantly.
• After the defrost operation, defrost LED indicator will lights
off.