3 Commissioning
3.1 Switching on and off
The plug socket on the vacuum cleaner will always be live when the
mains plug is plugged in, irrespectively of the position of the switch.
l CAUTION!
Electric tools and compressed air tools must be switched off
when they are connected
NOTE
If the switch is in the >0< position, the plug socket on the vacuum
cleaner can be use as an extension lead.
l Connection value: Vacuum cleaner + connected unit,
maximum 16 A.
▶ Insert the plug into socket
> 0 < Vacuum cleaner is switched off
> I < Vacuum cleaner switched on without shaker function
> IR < Vacuum cleaner switched on with automatic shaker
function
>AR< Vacuum cleaner on standby
The vacuum cleaner only switches on when the tool is
switched on.
After the tool is switched off, the vacuum cleaner runs on
for approx. 10 sec to prevent any residue from collecting
in the hose.
▶ Set the vacuum cleaner to the switch position >0<.
▶ Pull out the plug after you have fi nished.
▶ Fix the suction hose in the accessory storage location* on the
back of the container for storage.
▶ The ends of the hose can be pushed into each other to
prevent particles of dirt from coming out.
l CAUTION!
Selector switch for minimum material fl ow (horn and light)
on vacuum cleaners classes "M" and "H"
In the modes >AR< and >IR< the following setting is made,
depending on the diameter of the hose:
Inside diameter of the hose
 35 mm
 27 mm
 21 mm
No speed regulation is carried out.
The vacuum cleaner always runs at max. speed.
▷ Push the plug of the vacuum cleaner into the plug socket.
▷ Set the switch for normal operation without shaker function to "I"
and set it to "IR" for normal operation with shaker function and to
"AR" for standby mode.
↳ The vacuum cleaner is ready for suction.
▷ After vacuum cleaning, set the switch to "O".
▷ Pull the mains plug of the vacuum cleaner out of the plug socket.
▷ Secure the mains cable.
▷ Remove the electric/compressed air tool.
(* depending on the equipment variant)
4 Operating modes
▶ When using the grip handle you can adapt the suction perfor-
4.1 Dry vacuum cleaning
You should only use the vacuum cleaner with a dry fi lter and
appropriate accessories to prevent dust from accumulating and
forming encrustations.
When using the vacuum cleaner to remove soot, cement, plaster,
fl our or similar dust we recommend using fl eece fi lter bags. Always
use fi lter bags in combination with folding fi lter cassettes.
M, H and H Asbestos class vacuum cleaners should be
preferably used as dry vacuum cleaners.
4.2 Wet vacuum cleaning
Switch the vacuum cleaner off immediately if foam or liquid starts
to come out.
1
Switch position
▷ Vacuum cleaning without paper fi lter bags.
 35
 27
 21
▷ Empty the vacuum cleaner
If the vacuum cleaner is not switched off, the re-start protection
unit remains operative. Only after switching off and re-starting is
the vacuum cleaner ready for use again.
↳ The vacuum cleaner is switched off.
mance by using the slider to control access of air into the hose.
NOTE
l CAUTION!
Empty the container and, if necessary, the folding fi lter
cassette.
NOTE
Clean the water level sensors (1) regularly
and examine for signs of damage.
1
The folding fi lter cassettes are designed for wet vacuum
cleaning.
The fi tted sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be compromised
by a full container.