4 MAINTENANCE
TANK AND PIPES
Clean the instrument and its pipes after each use, with clean water.
Empty the tank complete. Never leave the sprayer phytosanitaries
products stored in the tank, pipes or pump.
FILTERS
This machine has the following lters:
- Filling tank lter ref. 9032.
- Output tank lter ref. 8702. It is located in the bottom of the tank
and can be removed for cleaning. After cleaning, reassembling in the
housing of the same way and position.
- Lance Filter , located inside the handle.
- Proper lter maintenance is the best guarantee for a smooth opera-
tion of your backpack. Clean these lters regularly (every working
day) and replace if a damaged.
DO NOT USE SOLVENTS, ACIDS, ABRASIVES PRODUCTS.
DO NOT IMMERSE IN WATER. DO NOT USE WATER
PRESSURIZED. EXTERIOR CLEANING USE DAMPED CLOTH
WITH NEUTRAL SOAP.
NOZZLES
The electric knapsack is supplied with quality nozzles.
The performance of this equipment may be DIMINISHED if using a
nozzle with excessive wear or if using a NOZZLE not recommended.
Replace the nozzle when present symptoms of deterioration.
22