Get function table:
Get Function
Length
Get-Contrast
8
Get-Brightness
8
Get-Sharpness
8
Get-Color
8
Get-Tint
8
Get-Volume
8
Get-Mute
8
Get-Input select
8
Get-Power
8
status : ON/
STBY
Get-Remote
8
control
Get-Power Lock
8
Get-Button Lock
8
Get-Menu Lock
8
Get-Tiling Mode
8
Get-Tiling
8
Compensation
Get-Tiling H by V
8
monitors
Get-Tiling
8
position
Get-ACK
8
Get-Thermal
8
Get-Power on/
8
off log
Get-Date
8
Get- Time
8
ID
Command
Type
Code (ASCII)
g
a
g
b
g
c
g
d
g
e
g
f
g
g
g
j
g
l
g
n
g
o
g
p
g
q
g
v
g
w
g
x
g
y
g
z
g
0
g
1
g
2
g
3
Command
Code (Hex)
(Three ASCII bytes)
61
000 ~ 100
62
000 ~ 100
63
000 ~ 100
64
000 ~ 100
65
000 ~ 100
66
000 ~ 100
67
000: OFF (unmuted)
001: ON (muted)
6A
000~
6C
000: STBY
001: ON
6E
000 : Disable
001 : Enable
002 : Pass through
6F
000 : Unlock
001 : Lock
70
000 : Unlock
001 : Lock
71
000 : Unlock
001 : Lock
76
000: OFF
001: ON
77
000: OFF
001: ON
78
01x~09x: H monitors
0x1~0x9: V monitors
79
000: OFF
001~025
7A
000
30
000~100:
0~+100 deg C
-01~-99:
-1~-99 deg C
31
000
(See below note)
32
000
(See the Set-Date
command)
33
000
(See the Set-Time
command)
31
Value Range
Comments
Gets Contrast value
Gets Brightness value
Gets Sharpness value
Gets Color value
Gets Tint value
Gets Volume value
Gets Mute ON/OFF
status
See Set-function table
(for DS)
(for DS)
Bezel width
compensation
(for DS)
1. 2
digital for H
nd
monitors
2. 3
digital for V
rd
monitors
(for DS)
Copy the screen of
Position# to identified
display
This command is
used to test the
communication link.
For specific models
only
For specific models
only
For specific models
only
For specific models
only

Publicidad

loading