EN
WARNING
Always make sure that the pressure relief valve is in the open (0) position, before you
connect hydraulic hose(s) to the pump.
•
Remove the dust caps from the female and male couplers.
•
Check the couplers for dirt and damage and clean them if necessary.
•
Screw the male coupler into the female coupler and tighten the locking ring as far as possible.
•
Screw the dust caps together, to prevent from contamination.
5.3
Disconnect the hydraulic hose
5.3.1
General
CAUTION
Never use pliers or similar tools to disconnect the hydraulic couplers.
5.3.2
Disconnect the High-flow couplers
Refer to Fig. 5.
WARNING
Always make sure that the pressure relief valve is in the open (0) position, before you
disconnect hydraulic hose(s) from the pump.
•
Disconnect the dust caps from each other.
•
Unscrew the locking ring. The male coupler will be released.
•
Clean the couplers and the dust caps.
•
Replace the dust caps on the female and male couplers.
6
Use
6.1
General
Check the equipment for completeness and damage. Do not use the equipment if it is damaged; in that
case contact the Holmatro dealer.
WARNING
Make sure you are up to date on all safety regulations and that you have mastered the use
of all equipment of the system you are going to work with.
6.2
Before use
•
Connect the hydraulic hose. Refer to section 5.2.
6.3
During use
WARNING
Wear personal means of protection at all times.
Never stand immediately behind the tool. These tools have enormous power.
24
916.219.170_006