Thank you for purchasing this Pfister product. All Pfister products are carefully engineered, and factory tested to provide long
trouble-free use under normal conditions. This product is easy to install using basic tools and our easy to follow illustrated
instructions. If you have any questions regarding this product, call 1-800-Pfaucet (1-800-732-8238).
1 BEFORE PROCEEDING
WARNING: Read all the instructions completely before proceeding. Pfister
recommends calling a professional if you are uncertain about installing this product!
This product should be installed in accordance with all local and state plumbing and
building codes.
This product has been designed for use with the Price Pfister 0W8-01 Wallmout
Valve Body. It will not work with any other product.
2
2 SHUT OFF WATER SUPPLY
Locate water supply inlets and shut off the water supply valves. These are usually found
under the sink or near the water meter. If you are replacing an existing faucet, remove
the old faucet from the sink and clean the sink surface thoroughly.
3
3 TOOLS RECOMMENDED
• PTFE Plumber's Tape
• Plumber's putty
• Adjustable wrench
• Pliers
• Cloth
Your installation may require new supply lines and / or shut-off valves or other additional
tools.
4
F
C
E
B
4 CHECKING THE CONTENTS OF THE BOX
Upon opening the box, check to ensure that all of the following items are included.
A Spout Body
B Handles (2x)
D Set Screw
E Valve Flange (2x)
If any of these items are missing, please contact Price Pfister Consumer Service at
1-800-Pfaucet (1-800-732-8238).
ENGLISH
• Slotted screwdriver
• Flashlight
D
F
E
B
A
C Spout Flange
F Seal Base (2x)
5
5A
5D
5E
FINISHED WALL
5E
5 VALVE BODY ADJUSTMENT
Remove all Plasterguards (5A). Loosen Collet Nut (5B) from Main Body (5C). Pull
the Spout Tube (5D) from the Main Body (5C) to the maximum position. Using the
end with the feet of Installation Tool (5E), push Outlet Tube (5D) in until Tool Feet (5F)
sit flat with Wall Surface as shown. Tighten Collet Nut (5B) by using the other end of
Installation Tool (5E) as shown.
2
5C
5A
FINISHED WALL
5C
5B
5D
5F
5D
5F
5F
5E
5B
5A