Descargar Imprimir esta página

Bühler technologies TF Serie Guía Rápida página 5

Sensor/interruptor de temperatura

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 8
TF, TS, Thermolog
The temperature sensor TF-M-Pt100-VAL was designed for
measuring storage temperatures and has a spring-loaded
sensor tube to allow installation free of play with a constant
contact pressure at the measuring point.
5.2 TSM/TSK/TSA Bi-Metal Temperature Switch
The TS temperature sensors have a bi-metal temperature
switch to signal a set temperature value. Unlike the TSM
standard version, the TSK and TSA versions with bi-metal
switches have a lower hysteresis.
The TSA version is further specifically designed for installation
in tube systems and cooling matrices.
The bi-metal switch is installed at the lowest point of the
sensor tube to always ensure sufficient contact with the me-
dium being measured.
5.3 Thermolog MK2/EK2 Temperature Sensor with
4-20mA Output
Type MK2 and EK2 temperature sensors use a Pt100 temperat-
ure sensor per DIN EN/IEC 60751 Class B to generate a temper-
ature-dependent resistance signal.
The built-in electronics convert this resistance signal into a
standard 4-20 mA two-lead signal.
The Pt100 sensor is installed at the lowest point of the sensor
tube to always ensure sufficient contact with the medium be-
ing measured.
6 Maintenance
Always observe the applicable safety- and operating regula-
tions when performing any type of maintenance. Please refer
to the original operator's manual on the included CD or online
at www.buehler-technologies.com for maintenance informa-
tion.
7 Service and Repair
Please refer to the original operator's manual on the included
CD or online at www.buehler-technologies.com for a detailed
description of the unit including information on
troubleshooting and repair.
8 Disposal
The applicable national laws must be observed when dispos-
ing of the products. Disposal must not result in a danger to
health and environment.
The crossed out wheelie bin symbol on Bühler Technolo-
gies GmbH electrical and electronic products indicates special
disposal notices within the European Union (EU).
The crossed out wheelie bin symbol indicates
the electric and electronic products bearing
the symbol must be disposed of separate
from household waste. They must be properly
disposed of as waste electrical and electronic
equipment.
Bühler Technologies GmbH will gladly dis-
pose of your device bearing this mark. Please
send your device to the address below for this
purpose.
BX140006 ◦ 07/2023
We are obligated by law to protect our employees from haz-
ards posed by contaminated devices. Therefore please under-
stand that we can only dispose of your waste equipment if the
device is free from any aggressive, corrosive or other operat-
ing fluids dangerous to health or environment. Please com-
plete the "RMA Form and Decontamination Statement", avail-
able on our website, for every waste electrical and electronic
equipment. The form must be applied to the packaging so it is
visible from the outside.
Please return waste electrical and electronic equipment to the
following address:
Bühler Technologies GmbH
WEEE
Harkortstr. 29
40880 Ratingen
Germany
Please also observe data protection regulations and remem-
ber you are personally responsible for the returned waste
equipment not bearing any personal data. Therefore please
be sure to delete your personal data before returning your
waste equipment.
Bühler Technologies GmbH
5

Publicidad

loading