INSTALLATION
Installing/Replacing the lamp
For the installation, you need one MSD/HSD 250 GY-9.5 or MSD 250/2 GY-9.5 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: To insert the lamp open the top cover of the head as in drawing 1. Loosen the Phillips screws on
the front and rear sides of the top cover and carefully remove them from the housing.
Step 2: Then open the small lamp cover by loosening the two fixation screws as in drawing 2.
Step 3: If changing a devective lamp, remove the old lamp from the socket.
Step 4: Carefully insert the new lamp to the socket.
Step 5: Adjust the optimal distance between lamp and lens by turning screw „A".
Step 6: Close the lamp cover and tighten the fixation screws.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
26/68