DEACTIVATING AUTOMATIC REOPENING
The automatic reopening function can be deactivated at any moment with the following
command sequence:
Tn: Already programmed remote control
+
A
B
Tn
The light level point can be set using the button
provided in the lower part of the WindTec Lux sensor,
identified by the sun symbol.
The light intensity can be set from a minimum of 2.5 kLux (dawn light) up to a maximum of
100 kLux (midday sunlight). To activate the automatic awning opening, the light intensity
must exceed the set level for 1 minute, while for automatic closing, the light intensity
must remain below the set level for at least 10 minutes. These pause times are included
to prevent the motor from moving continuously in the event of passing clouds. Automatic
opening and closing only work when the motor is set to the automatic wind + light mode.
ACTIVATING THE AUTOMATIC OR MANUAL SETTING MODE
BY THE REMOTE CONTROL SERIES SKIPPER
The manual mode (wind only), or automatic mode (wind +
sun) setting has to be done by the Skipper Lux or Skipper P-Lux
remote control. By briefly pressing the "SEL" button, the remote
control shows the current setting.
To change the setting press the SEL button again and hold it down for around 2 sec, until
the motor replies with a confirmation sequence.
SEL
Tn
- only with Blue Wave RX motors -
C
Tn
SETTING THE SUN SENSOR
(WindTec Lux)
SEL
Tn (2 sec)
24
A
Tn (2 sec)
"SUN LIGHT"
SETTING
Wind & Sun sensor
activate.