1-Phase Power Supplies Instruction Manual
Bedienungsanleitung für 1-Phasen Stromversorgungen
1)
Technical Data
Output Voltage
Factory Setting at Full Load
Output Current
continuous
Output Current
for typical 4s
Output Power
continuous
Output Power
for typical 4s
2)
Output Ripple & Noise Voltage
AC Input Voltage
Input Frequency
3)
AC Input Current
3)
Power Factor
Allowed Voltage L or N to Earth
EN 61000-3-2
4)
Input Inrush Current
13)
DC Input Voltage
3)
Hold-up Time
3)
Efficiency
3)
Power Losses
Operational Temperature Range
Output Derating
Storage Temperature Range
5)
Humidity
Vibration
Shock
Degree of Pollution (non-conductive) Verschmutzungsgrad (nicht leitend)
Degree of Protection
Class of Protection
Over-temperature Protection
Output Over-voltage Protection
7)
Touch (Leakage) Current
8)
Return Voltage Resistance
11)
Parallel Use
12)
Serial Use
9)
Dimensions
(WxHxD)
Weight
Approvals
Limited Warranty
1) All parameters are specified at 230Vac input voltage, nominal output current, "Single Use"
setting, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
2) 50-Ohm measurement, bandwidth 20MHz
3) at 120Vac / 230Vac
4) Input inrush current is electronically limited and temperature independent.
5) Do not energize while condensation is present.
6) PE connection required (Ground).
7) Leakage current at 132Vac, 60Hz / 264Vac, 50Hz, TT/TN-mains
8) Loads such as decelerating motors and inductors can feed voltage back to the output of the
power supply. The figure represents the maximum allowed feed back voltage
9) Depth without DIN-rail.
10) See datasheet or markings on the unit.
11) Set jumper on the front to "Parallel Use". A fuse (or diode) on the output is required if more
than three units are paralleled.
12) Use only power supplies of the same type. The total output voltage should not be >150Vdc.
13) Additional tests might be necessary when the complete system has to be approved according
to UL standards. A supply from the intermediate DC-bus of a drive system is not
recommended. Use appropriate external fuses which are suitable for the DC-voltage.
Installation
Use DIN-rails according to EN 60715 or EN 50022 with a height of 7.5 or 15mm. Mounting
orientation must be output and input terminals on the bottom. For other orientations see
datasheet. Do not obstruct air flow as the unit is convection cooled. Ventilation grid must be kept
free of any obstructions. The following installation clearances must be kept when power supplies
are permanently fully loaded:
Left / right: 5mm (15mm in case the adjacent device is a heat source)
40mm on top, 20mm on the bottom of the unit.
Input Fuses
Internal input fuse: T12.5A (H.B.C.), not user accessible. The unit is tested and approved for
branch circuits up to 32A. An external protection is only required if the supplying branch has an
ampacity greater than this, however, in some countries local regulations might apply. Check local
codes and requirements. If an external fuse is necessary or utilized, minimum requirements need
to be considered to avoid nuisance tripping of the circuit breaker. A minimum value of 10A B- or
8A C-Characteristic breaker should be used.
Terminals and Wiring
(see Fig. 6)
Use appropriate copper cables that are designed for a minimum operating temperature of 60°C
(for ambient up to 45°C) and 75°C (for ambient up to 60°C). Follow national installation codes and
regulations! Ensure that all strands of a stranded wire enter the terminal connection! Up to two
stranded wires with the same cross section are permitted in one connection point (except PE
wire). Ferrules are allowed, but not required.
Input
2
Solid wire
0.5-6mm
2
Stranded wire
0.5-4mm
American wire gauge
20-10 AWG
Wire stripping length
7mm / 0.28inch
Tightening torque
0.8Nm / 7lb.inch
1)
Technische Daten
Ausgangsspannung
Werkseinstellung bei Nennlast
Ausgangsstrom
dauernd
Ausgangsstrom
für typisch 4s
Ausgangsleistung
dauernd
Ausgangsleistung
für typisch 4s
2
Ausgangswelligkeit
)
AC Eingangsspannung
Eingangsfrequenz
3)
AC Eingangsstrom
3)
Leistungsfaktor
Erlaubte Spannung L oder N zu Erde
EN 61000-3-2
4)
Einschaltspitzenstrom
13)
DC Eingangsspannung
3)
Pufferzeit
3)
Wirkungsgrad
3)
Verlustleistung
Betriebstemperaturbereich
Leistungsrücknahme
Lagertemperaturbereich
5)
Feuchte
Schwingen
Schocken
Schutzart
Schutzklasse
Übertemperaturschutz
Überspannungsschutz am Ausgang
7)
PE- Ableitstrom
8)
Rückspeisefestigkeit
11)
Parallelschaltbar
12)
Serienschaltbar
9)
Abmessungen
(BxHxT)
Gewicht
Zulassungen
Gewährleistung
Output
Signals
2
0.5-16mm
0.15-1.5mm
2
0.5-10mm
0.15-1.5mm
22-8 AWG
26-14 AWG
12mm / 0.5inch
7mm / 0.28inch
1.2Nm / 10.6lb.inch
Spring-clamp terminal
QS40.244
nom.
DC 24-28V
"Single-Use", typ.
nom.
40A (24V), 34.3A (28V)
nom.
60A (24V), 51.5A (28V)
nom.
nom.
max.
100mVpp
nom.
AC 200-240V
-15%/+10%
nom.
50-60Hz
typ.
typ.
max.
300Vac
PFC-Norm
Yes / Ja
typ.
14A peak
nom.
-20%/+25%
DC 220-300V
typ.
- / 30ms
typ.
- / 94.6%
typ.
- / 54.8W
nom.
-25°C - +70°C
+60°C to +70°C
24W/°C
nom.
-40°C - +85°C
IEC 60068-2-30
5 - 95% r.H.
IEC 60068-2-6
IEC 60068-2-27
15g 6ms, 10g 11ms
EN 50178 / 62103
EN 60529
IEC 61140
OTP
Yes / Ja
OVP, max.
max.
- / 0.8mA
max.
-
Yes / Ja
-
Yes / Ja
nom.
125x124x127mm
max.
-
Years / Jahre
1) Alle Werte gelten bei 230Vac Eingangsspannung, Nennausgangsstrom, „Single-Use" Modus,
25°C Umgebung und nach einer Aufwärmzeit von 5 Minuten, falls nichts anderes angegeben.
2) 50-Ohm Messung, Bandbreite 20MHz
3) bei 120Vac / 230Vac
4) Der Einschaltstromstoß ist elektronisch begrenzt und temperaturunabhängig.
5) Nicht betreiben, solange das Gerät Kondensation aufweist.
6) PE Verbindung erforderlich.
7) Ableitstrom bei 132Vac, 60Hz / 264Vac, 50Hz, TT/TN-Netze
8) Bremsende Motoren oder Induktivitäten können Spannung zum Ausgang des Netzteils
rückspeisen. Der Wert gibt die max. zulässige Rückspeisespannung an.
9) Tiefe ohne DIN-Schiene
10) Siehe Datenblatt oder Prüfzeichen auf dem Gerät.
11) Steckbrücke an der Front des Gerätes auf „Parallel Use" umstellen. Bei mehr als drei Geräten
wird eine Sicherung oder eine Diode zur Entkopplung benötigt.
12) Nur für gleiche Geräte bis zu einer Gesamtspannung von 150Vdc
13) Zusätzliche Tests können bei der Zulassung des Gesamtsystems nach UL Normen
erforderlich sein. Ein Betrieb am Zwischenkreis von Frequenzumrichtern wird nicht
empfohlen. Es ist erforderlich eine für die DC-Spannung geeignete Sicherung vorzuschalten.
Installation
Geeignet für DIN-Schienen entsprechend EN 60715 oder EN 50022 mit einer Höhe von 7,5 oder
15mm. Der Einbau hat so zu erfolgen, dass sich die Eingangs- und Ausgangsklemmen unten
befinden. Für andere Einbaulagen siehe Datenblatt. Luftzirkulation nicht behindern! Das Gerät ist
für Konvektionskühlung ausgelegt. Es ist für ungehinderte Luftzirkulation zu sorgen. Folgende
Einbauabstände sind bei dauerhafter Volllast einzuhalten:
Links / rechts: 5mm (15mm bei benachbarten Wärmequellen)
Oben: 40mm, unten 20mm vom Gerät.
Sicherungen am Eingang
Das Gerät besitzt eine T12,5A (H.B.C.) Eingangssicherung, die nicht anwenderzugänglich ist. Das
Gerät ist geprüft und zugelassen zum Anschluss an Stromkreisen bis max. 32A. Ein zusätzlicher
externer Schutz ist nur erforderlich, wenn der Speisestromkreis mit einem höheren Wert
abgesichert ist oder nationale Richtlinien es vorschreiben. Falls ein externes Schutzelement
verwendet wird, soll dieses nicht kleiner als 10A B- oder 8A C-Charakteristik sein, um ein
fehlerhaftes Auslösen zu vermeiden.
Anschlussklemmen und Verdrahtung
Verwenden Sie geeignete Kupferkabel, die mindestens für 60°C bei einer Umgebungstemperatur
bis zu 45°C und 75°C bei einer Umgebungstemperatur bis zu 60°C zugelassen sind. Beachten
Sie nationale Bestimmungen und Installationsvorschriften! Stellen Sie sicher, dass keine
einzelnen Drähte von Litzen abstehen. Bis zu zwei Leiter mit gleichem Querschnitt sind in einem
Anschlusspunkt zulässig (außer Schutzleiter). Aderendhülsen sind erlaubt, aber nicht erforderlich.
2
Starrdraht
2n
Litze
AWG
Abisolierlänge
Anzugsdrehmoment
QS40.484
DC 48-54V
24.1V
48.0V
20A (48V), 17.8A (54V)
30A (48V), 26.7A (54V)
960W
960W
1440W
1440W
150mVpp
AC 200-240V
-15%/+10%
±6%
±6%
50-60Hz
- / 4.6A
- / 4.6A
- / 0.96
- / 0.96
300Vac
Yes / Ja
14A peak
-20%/+25%
DC 220-300V
- / 30ms
- / 95.0%
- / 50.5W
-25°C - +70°C
24W/°C
-40°C - +85°C
5 - 95% r.H.
1g
1g
15g 6ms, 10g 11ms
2
2
IP20
IP20
6)
6)
I
I
Yes / Ja
32Vdc
60Vdc
- / 0.8mA
35Vdc
63Vdc
Yes / Ja
Yes / Ja
125x124x127mm
1800g
1800g
10)
10)
3
3
(siehe Bild 6)
Eingang
Ausgang
2
2
0.5-6mm
0.5-16mm
2
2
0.5-4mm
0.5-10mm
20-10 AWG
22-8 AWG
7mm / 0.28inch
12mm / 0.5inch
0.8Nm / 7lb.inch
1.2Nm / 10.6lb.inch
Signale
2
0.15-1.5mm
2
0.15-1.5mm
26-14 AWG
7mm / 0.28inch
Federkraftklemme