ELECTRICAL SAFETY
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your TOTAL tool is double insulated
in accordance with EN 60745:
therefore no earth wire is required.
Assembly and adjustment
NOTE: Before using the tool,
Read the instruction book
Carefully. Prior to assembly and
adjustment always unplug the
tool
Prior to assembly and adjustment
always unplug the tool.
CHANGING THE TOOL
picture 2
Before any work on the machine itself, pull
the mains plug.
When working with an application tool,
pay attention that the application tool is
firmly seated on the tool holder. when the
application tool is not firmly connected with the
tool holder, it can come loose again and not be
controlled.
Slide the application tool onto the square drive
of the tool holder.
Reference Values for Maximum Screw/Bolt Tightening Torques
Calculated from the tensional cross-section; utilization of the yield point 90% (with friction coefficient μ
measure, always check the tightening torque with a torque wrench.
Property Classes
Screw
according to DIN267
size
M6
10
M8
13
M10
17
M12
19
M14
21(22)
M16
23
M18
27
M20
30
Standard Screws/Bolts
3.6
4.6
5.6
4.8
2.71
3.61
4.52
4.8
6.57
8.7
11
11.6
13
17.5
22
23
22.6
30
37.6
40
36
48
60
65
55
73
92
98
75
101
126
135
107
143
178
190
INSTRUCTIONS FOR
USE
Always observe the safety
The voltage of the power source
specified on the nameplate of
the machine
REVERSING THE ROTATIONAL DIRECTION
Counterclockwise
picture 3
Clockwise: Press lower part the ON/OFF switch
and keep it pressed.
Counterclockwise: Press upper part the ON/
OFF switch and keep it pressed.
SWITCHING ON AND OFF
To start the machine, press the ON/OFF switch
and keep it pressed.
To switch off the machine, release the ON/OFF
switch.
When not using power tool, switch it off in
order to save energe.
6.6
5.8
6.8
6.9
5.42
6.02
7.22
8.13
13.1
14.6
17.5
19.7
26
29
35
39
45
50
60
67
72
79
95
107
110
122
147
165
151
168
202
227
214
238
286
320
8
instructions and applicable
regulations
Observe correct mains voltage!
must agree with the voltage
Clockwise
=0.12). As a control
total
High-strength Bolts
8.8
10.9
12.9
9.7
13.6
16.2
23
33
39
47
65
78
80
113
135
130
180
215
196
275
330
270
380
450
385
540
635