E N G L I S H
LOUDSPEAKERS LINE OUT
8
The loudspeakers line out is effected by means of a transformer that has
low impedance outputs (4 – 8 – 16 Ohms) and high impedance outputs
(50 – 70 – 100V).
The connection must be made between terminal "0" and the terminal
corresponding to the appropriate impedance or voltage.
Low impedance
One of these three outputs will be used when the loudspeakers do not have a line transformer, and it will be
selected in such a way that the loudspeaker line impedance is the same as the impedance of the amplifi er
output contact.
High impedance
When working with the 50, 70 and 100V lines, it should be remembered that:
The loudspeakers to be connected must have a line transformer.
Eng
The total connected power will be the sum of the power absorbed by the loudspeakers and this must be
between 50% below and 20% above the rated power of the amplifi er.
The power absorbed by a loudspeaker with a transformer is indicated on its terminals.This power is on the
100V line. If the transformer is connected to the 70V line, it will absorb half the indicated power, and if it is
connected to the 50V line, it will absorb a quarter of this power. A 30W transformer will absorb 15W if it is
connected to the 70V line and 7.5W if it is connected to the 50V line.
100V.
0
T1
A
10W
70V.
0
T1
B
10W
50V.
0
T1
C
10W
A. Total input power 60W. Power absorbed by each 10W transformer = 10W
B. Total input power 60W. Power absorbed by each 10W transformer = 5W
C. Total input power 60W. Power absorbed by each 10W transformer = 2.5W
100V.
0
T1
A
40W
70V.
0
T1
B
40W
50V.
0
T1
C
40W
A. Total input power 240W. Power absorbed by each 40W transformer = 40W
B. Total input power 240W. Power absorbed by each 40W transformer = 20W
C. Total input power 240W. Power absorbed by each 40W transformer = 10W
1 6
AMPLIFIERS UP-366, UP-246, UP-126 and UP-66
UP-66
T2
T5
10W
10W
10W
10W
10W
10W
T2
T11
5W
5W
5W
10W
10W
10W
T2
T23
2.5W
2.5W
2.5W
10W
10W
10W
UP-246
T2
T5
40W
40W
40W
40W
40W
40W
T2
T11
20W
20W
20W
40W
40W
40W
T2
T23
10W
10W
10W
40W
40W
40W
100V.
0
T6
A
10W
70V.
0
T12
B
5W
20W
50V.
0
T24
C
2.5W
20W
A. Total input power 120W. Power absorbed by each 20W transformer = 20W
B. Total input power 120W. Power absorbed by each 20W transformer = 10W
C. Total input power 120W. Power absorbed by each 20W transformer = 5W
100V.
0
T6
A
40W
70V.
0
T12
B
20W
60W
50V.
0
T24
C
10W
60W
A. Total input power 360W. Power absorbed by each 60W transformer = 60W
B. Total input power 360W. Power absorbed by each 60W transformer = 30W
C. Total input power 360W. Power absorbed by each 60W transformer = 15W
Figure 3
O U T P U T S
0
4Ω 8Ω 16Ω
UP-126
T1
T2
T5
20W
20W
20W
20W
20W
20W
T1
T2
T11
10W
10W
10W
20W
20W
T1
T2
T23
5W
5W
5W
20W
20W
UP-366
T1
T2
T5
60W
60W
60W
60W
60W
60W
T1
T2
T11
30W
30W
30W
60W
60W
T1
T2
T23
15W
15W
15W
60W
60W
Version 1.1
UP-366, UP-246, UP-126 and UP-66
SURETY PAGING
50V 70V 100V
T6
20W
20W
T12
10W
20W
T24
5W
20W
T6
60W
60W
T12
30W
60W
T24
15W
60W