VIEW BUttON
• Displays the charger data, e.g. input voltage. This button can also be used to display all
the individual cell voltages of a LiPo battery connected to the charger.
• Pressing this button returns you to the working screen from any menu.
all buttons have an auto-repeat function: holding the button pressed in causes the
appropriate function to be triggered repeatedly.
INtEGRaL SOUNDER
• The piezo buzzer confirms each button-press, and provides an audible indication that the
charge / discharge process is finished. It also alerts the user to errors.
4.
SPECIfICatION
Operating voltage:
Cell count:
Charge current:
Discharge current:
Equalizing current:
Charge power:
Discharge power:
Trickle charge:
Final discharge voltage.: 0.8 V per cell, NC and NiMH,
Charge termination:
NC / NiMH:
Lead and lithium:
Dimensions:
Functions:
All manuals and user guides at all-guides.com
Operating Instructions
Power Peak ® B7 EQ-BID
12 V DC (car battery) / 230 V AC mains PSU operation
(Do not use a car battery charger as power supply!)
1 ... 16 cells NC / NiMH,
1 ... 7 cells LiIo (3.6 V), LiPo (3.7 V), LiFe (3.3 V)
1 ... 12 cells (2...24 V) lead-acid battery
0.1 ... 10 A at max. 50 W
0.1 ... 10 A at max. 5 W
max. 280mA
50 W, current is reduced when necessary
e.g. 24 V battery voltage, charge current approx. 2.0 A
5 W, current is reduced when necessary
e.g. 4.8 V battery voltage, discharge current approx. 1.0 A
C/10 min.= 100 mA
Min.= 500 mA (NC and NiMH only)
3.0 V per cell for LiPo, Lilo
2.5 V per cell for LiFe
1.8 V per cell for lead-acid batteries
automatic, digital Delta-Peak system
automatic, voltage-dependent, CC-CV method
130 x 80 x 35 mm
Charge, discharge, discharge-charge, balance
4 internal battery memories