Descargar Imprimir esta página

Southwire 31040S Instrucciones De Operación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Introduction
The Southwire 31040S Infrared Thermometer measures surface temperature
without contact from -58° to 1500°F (-50° to 815°C). Dual lasers pinpoint the
target area and the 20:1 distance to spot size ratio allows measuring objects
at greater distance. Other features include fast response, MAX display, user
settable High/Low alarms, backlit display and adjustable emissivity. Proper
use and care of this meter will provide many years of reliable service.
SAFETY
• Use extreme caution when the laser beam
is turned on.
• Do not aim the laser beam at anyone's eye or let
the laser beam strike the eye from a reflective surface.
• Do not use meter near explosive gases, vapors or dust.
• To avoid burns, understand that reflective objects can be
much hotter than the meter indicates.
• Replace the battery as soon as the low battery warning
appears on the LCD display.
• Do not use the meter if it appears damaged or is operating improperly.
• This product is intended for commercial and industrial use only.
It should not be used for medical evaluations.
Maintenance
This meter is designed to provide years of dependable service, if the following
care instructions are performed.
• KEEP THE METER DRY. If it gets wet, wipe it off.
• USE AND STORE THE METER IN NORMAL TEMPERATURES. Temperature extremes
can shorten the life of the electronic parts and distort or melt plastic parts.
• HANDLE THE METER GENTLY AND CAREFULLY.
Dropping it can damage the electronic parts or the case.
• KEEP THE METER CLEAN. Wipe the case occasionally with a damp cloth.
DO NOT use chemicals, cleaning solvents, or detergents.
• USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE.
Remove old or weak batteries so they do not leak and damage the unit.
• IF THE METER IS TO BE STORED FOR A LONG PERIOD OF TIME,
the batteries should be removed to prevent damage to the unit improperly.
1
Meter Description
1. IR sensor,
1.
Laser pointer beams
2. LCD display
3. Up button
4. Down button
5. MODE button
6. Measurement trigger
7. Battery cover
8. Handle grip
Buttons
Up button (3.) (for laser on/off, and increasing values
in EMS, HAL, LAL settings)
Down button (4.) (for backlight on/off, and decreasing
values in EMS, HAL, LAL settings)
MODE button (5.) (for cycling through the MODE loop
Display Description
1. Data hold
2. Laser on symbol
3. Lock symbol
4. High alarm and low alarm symbols
5. °F/°C symbols
6. Low battery symbol
7. Emissivity symbol and value
8. MAX temperature
9. Symbol for MAX
10. Temperature reading
3.
6.
7.
3.
4.
1.
2.
10.
9.
8.
7.
2
2.
4.
5.
8.
5.
6.

Publicidad

loading

Productos relacionados para Southwire 31040S