TECHNICAL DATA
Nominal power output ..................................................................
Rated output .................................................................................
No-load speed, 1st gear ...............................................................
No-load speed, 2nd gear ..............................................................
Speed under load max., 1st gear .................................................
Speed under load max., 2nd gear ................................................
Rate of percussion under load max. .............................................
Drilling capacity in concrete ..........................................................
Drilling capacity in brick and tile ...................................................
Drilling capacity in steel ................................................................
Drilling capacity in Aluminium .......................................................
Drilling capacity in wood ...............................................................
Drill opening range .......................................................................
Drive shank ..................................................................................
Chuck neck diameter ....................................................................
Weight without cable ....................................................................
Typical weighted acceleration in the hand-arm area ....................
Typical A-weighted sound levels:
Sound pressure level .................................................................
Sound power level .....................................................................
Wear ear protectors! Measured values determined according to EN 50 144.
The data stated above apply for models with 230 - 240 V. In case of deviating mains voltage, the data stated on the rating plate are
applicable.
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the attached
leaflet!
Appliances used at many different locations including open air
must be connected via a current surge preventing switch.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes and
apron.
Sawdust and splinters must not be removed while the machine
is running.
Always disconnect the plug from the socket before carrying out
any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
Always use the auxiliary handle, even if the machine has a
safety clutch since this safety clutch only engages when the
machine blocks with a jerk.
When working with large drill diameters, the auxiliary handle
must be fastened in a right angle with the main handle (see
illustrations, section „Twisting the handle").
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The percussion drill can be universally used for drilling and
percussion drilling.
Do not use this product in any other way as stated for normal
use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also possible
to connect to sockets without an earthing contact as the design
conforms to safety class II.
15
ENGLISH
SB2-1010 D ST
........................ 1010 W ............................ 900 W
.......................... 505 W ............................ 450 W
.......................... 800 min
........................ 150 min
-1
........................ 1800 min
...................... 1000 min
-1
.......................... 650 min
........................ 450 min
-1
........................ 1350 min
...................... 1000 min
-1
........................ 1600 min
............................. -
-1
............................ 35 mm ............................... -
............................ 40 mm ............................... -
............................ 16 mm ............................ 16 mm
............................ 20 mm ............................ 20 mm
............................ 50 mm ............................ 40 mm
......................... 3-16 mm ......................... 3-16 mm
...................M18x2,5 .........................M18x2,5
............................ 57 mm ............................ 57 mm
........................... 4,2 kg ............................. 4,2 kg
............................ 10 m/s
........................... 10 m/s
2
.......................... 100 dB (A) ........................ 86 dB (A)
...........................113 dB (A) ........................ 99 dB (A)
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized
documents. EN 50144, EN 55014-1, EN 55014-2, EN 61000-3-
2, EN 61000-3-3, in accordance with the regulations 98/37/EC,
89/336/EEC
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Use only AEG accessories and spare parts. Should
components need to be exchanged which have not been
described, please contact one of our AEG service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the ten-digit No. as well as the machine type printed on
the label and order the drawing at your local service agents or
directly at: AEG Elektrowerkzeuge, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Always disconnect the plug from the socket
before carrying out any work on the machine.
Accessory - Not included in standard
equipment, available as an accessory.
B2E 900 RD ST
-1
-1
-1
-1
2
Volker Siegle
Manager Product Development

Publicidad

loading

Este manual también es adecuado para:

B2e 900 rd super torque