Descargar Imprimir esta página

Facom NJ.1400F2 Manual Original página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
PLACING THE MACHINE IN SERVICE
LUBRIFICATION
Always use of an air line lubricator with these machine. We recommended the
following Filter-Lubricator-Regulator Unit: FACOM N.580.
Every eight hours' operation, if a lubricator is not used on the compressed air
network, inject 1/2 to 1cm
through the machine's inlet connection.
3
Model
Square
Impact
drive
rate
''
NJ.1400F2
3/8
660
Model
Free speed
rpm
NJ.1400F2
12000
* k = measurement uncertainty in dB
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
WE, FACOM S.A.S., 6/8 RUE GUSTAVE EIFFEL - BP 99 - 91 423 MORANGIS CEDEX FRANCE, DECLARE UNDER OUR OWN RESPONSIBILITY THAT THE
PRODUCT NJ.1400F2 – FACOM 3/8" AIR IMPACT WRENCH
- IS IN CONFORMITY WITH THE «MACHINERY» DIRECTIVE 2006/42/CE
- AND IS IN CONFORMITY WITH THE PROVISIONS OF THE HARMONISED EUROPEAN STANDARD EN ISO 11148-6: 2010
EN ISO 12100:2010
EN ISO 15744:2008
EN ISO 28927-2:2009
• BEFORE EACH OPERATION, CHECK:
- Only use suitable FACOM sockets and flogging spanner accessories, (''IMPACT'') as well as
safety devices, bush and pin for mounting one of these cases on a drilled driving
square.
- The drive square condition (no marks, cracks or excessive wear).
- The condition of the safety devices (bush and pin) on the drilled square as well as the draw
bead on the non-drilled square.
Recommended
Maximum
dynamic
dynamic
torque
torque
N.m
N.m
85
95
Air consumption
Working pressure
l/min
bar
48
6,2
** k = measurement uncertainty in m/s²
CE DECLARATION OF CONFORMITY
CE DECLARATION OF CONFORMITY
EMERGENCY
GATE VALVE
Noise level
Pressure dB(A)
Power dB(A)
k*
96
3
107
Weight
Dimensions
kg
0,53
140x54x40
Pressure dB(C)
k*
k*
3
110
3
7,0
mm
20.03.2013
F
ACOM QUALITY MANAGER
Vibrations
level
m/s
2
k**
1,19

Publicidad

loading

Este manual también es adecuado para: