Descargar Imprimir esta página

AUX ALCA-12-NHB Manual De Instalación Y Usuario página 59

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5. TROUBLESHOOTING
5.1.
T roubles and causes of air conditioner
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures.
Table 5-1 Error codes displayed on the receiver display of the indoor unit or on the wired remote control
Code
Unit
1
AA
Indoor Communication failure of wire controller
A1
Indoor Indoor ambient temp sensor failure
2
3
A2
Indoor Indoor coil temp sensor failure
A3
Interior Fault with the liquid pipe temperature sensor on indoor unit
4
5
A4
Interior Fault with the gas pipe temperature sensor on indoor unit
A5
Indoor Drain pump failure
4
5
A6
Indoor Indoor fan motor failure
A8
Indoor Indoor unit EPROM failure
6
7
A9
Indoor Communication failure between indoor unit and outdoor unit
AJ
Interior Fault with anti-Frozen protection of indoor unit in heating model
8
E5
Interior Communication failure of wired controller
9
Indoor Indoor high temp protection in heating
10
E8
Outdoor Overload protection in cooling mode
11
31
Outdoor IPM module protection (F0)
32
Outdoor IPM module hardware protection
12
13
33
Outdoor IPM module software protection
34
Outdoor Compressor unconnected
14
15
35
Outdoor Over power current protection
Over/low power voltage protection
16
36
Outdoor
Over/low main line voltage protection
37
Outdoor Outdoor module heat fins temp sensor failure
17
18
38
Outdoor Fault with the Compressor Power supply Phase deficiency protection
39
Outdoor IPM module protection
19
20
C1
Outdoor Outdoor ambient temp sensor failure
C2
Outdoor Outdoor coil temp sensor failure
21
C3
Outdoor Outdoor discharge temp sensor failure
22
23
C6
Outdoor Suction temp sensor failure
C8
Outdoor Outdoor defrost temp sensor failure
24
25
E3
Outdoor High discharge temp protection
FH
Outdoor Low discharge temp protection
26
27
E1
Outdoor 4way-valve failure
F1
Outdoor Outdoor DC fan motor failure
28
29
F6
Exterior Fault with the low pressure
H1
Outdoor High pressure switch protection
30
31
H4
Outdoor Low pressure switch protection
Communication failure between the driver PCB and main PCB
32
J6
Indoor
of the indoor unit
J3
Outdoor Communication failure between PCB and IPM module
33
3H/5H Outdoor Communication failure between main PCB and DC fan motor module
34
J7
Outdoor Main control PCB EPROM failure
35
3E
Outdoor DC inverter compressor running out of step
36
Please cut off the power supply when appearing the
above malfunction, check if the voltage provided is out of
range, check if the installation of air-conditioner is
correct, then electrify again after 3 minutes power off. If
the problem is still existent, please contact the local
service station or the equipment provider.
Description
59
CAUTION

Publicidad

loading