QS10 Power Supply Instruction Manual
Technical Data
Output Voltage
Factory Set
typ.
Output Current
min
min
Output Power
min.
min.
Output Ripple
max.
Over-voltage Protection
max.
AC Input Voltage
-
AC Input Current
max.
DC Input
-
DC Input Current
max.
Power Factor
typ.
AC Inrush Current
max.
Efficiency
typ.
Losses
typ.
Hold-up Time
typ.
Capacitive Loads
-
Inductive Loads
-
Limited Warranty
-
Functional Diagram
L
Input Fuse
Input Filter
N
Input Rectifier
Active Transient Filter &
Inrush Current Limiter
Temper-
Output
ature
Power
Shut-
Manager
down
DC-ok Relay Contact
This feature monitors the output voltage, which is produced by the power supply, and is
independent of a return voltage from a unit which is connected in parallel.
Contact closes as soon as the output voltage reaches the nominal value.
Contact opens as soon as the output voltage dips more than 10%.
Short dips will be extended to a length of 250ms on the relay.
Dips shorter than 1ms will be ignored.
Contact ratings 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A, resistive load
V
V
ADJ
OUT
90%
V
ADJ
< 1ms
closed
open
Please note:
The DC-ok feature requires that the output voltage reach the nominal (=adjusted) level after
turn-on in order to function to specification. If this level cannot be achieved, the unit will show
an overload condition. The overload signal will disappear as soon as the adjusted voltage is
reached. This is an important to condition to consider particularly, if the load is a battery or
the power supply is used for N+1 redundant systems.
Environment
Operational temperature
Storage temperature
Humidity
Vibration sinusoidal
Shock
Allowed output current versus
the ambient temperature
Ambient temperature is defined
2cm below the unit.
QS10.241
QS10.121
DC 24-28V
DC 12-15V
24.1V
12.0V
10-9A
15-13.5A
15-13.5A
22.5-18A
240W
180W (at 12V)
360W
270W
50mVpp
50mVpp
39Vdc
20Vdc
AC 100-240V
2.8-1.2A
2.2-1.0A
DC 110-300V -20/+25%
2.4-0.9A
2.0-0.7A
0.99-0.92
10A peak, 1A
92.3 / 93.0%
91.5 / 91.8%
20.0 / 18.1W
16.7 / 16.1W
27ms
32ms
No limitations
No limitations
Output
Voltage
Regulator
Output
Power
PFC
Filter
Converter
Converter
Output
Output
Over-
Voltage
Voltage
Monitor
Protection
DC-ok
Relay
10%
250ms
> 1ms
open
-25 to +70°C
De-rate above +60°C
-40 to +85° C
Storage, transport
5 to 95% RH
No condensation allowed
2g
IEC 60068-2-6
30g 6ms, 20g 11ms
IEC 60068-2-27
150%
for ty p. 4s
125%
100%
continuous
75%
50%
25%
Ambient Temperature
0%
-40°C -20°C 0°C
20°C 40°C 60°C 80°C
QS10.301
QS10.481
DC 28-32V
DC 48-56V
30.0V
48.0V
8.5-7.5A
5-4.3A
12.75-11.25A
7.5-6.5A
240W
240W
360W
360W
50mVpp
100mVpp
45Vdc
60Vdc
, 50-60Hz
-15/+15%
2.8-1.2A
2.8-1.2A
2.4-0.9A
2.4-0.9A
2
s
92.3 / 93.0%
91.2 / 92.0%
20.0 / 18.1W
23.2 / 20.9W
22ms
27ms
3 year
Dielectric Strength
Input
L
V
OUT
N
+
+
A
-
-
Earth
Overload
lamp
DC-ok
lamp
DC-ok
contact
Overload Performance
28V
24V
20V
16V
12V
8V
4V
0V
0A
Output characteristic (typ.)
Curve is valid for the 24V unit. Units with
output voltages other than 24V have an
equivalent and proportional performance
Repetitive pulse loading: Multiple pulses can be supported as long as the average (R.M.S.)
output current stays below the specified continuous output current. If it is higher, the unit will
respond with a thermal shut-down.
P
closed
OUT
max.
150%
100%
0%
Protection
Output
Degree of protection
Class of protection
Degree of pollution
Over-temperature protection
Output over-voltage protection
Over-voltage category
Penetration protection
Internal input fuse
External fuse on input
The unit is tested and approved for branch circuits up to 20A. External protection is only
required, if the supplying branch has an ampacity greater than this. In some countries local
regulations might apply. Check also local codes and local requirements. If an external fuse is
necessary or utilized, a minimum value of B6A or C4A is required to avoid a wrong tripping of
the circuit breaker.
externally adjustable
at full rated load
continuous
for typ. 4 sec
continuous
for typ. 4 sec
BW DC to 20MHz
TN, TT and IT mains
at 100-240Vac
at 110 - 300Vdc
at 100 - 230Vac
at 120 / 230Vac
at 120 / 230Vac
at 120 / 230Vac
at 100 - 240Vac
Type tests and factory tests:
DC-ok
Conducted by the manufacturer.
B
Do not repeat test in field!
Field test rules:
(1) Use appropriate test equipment which
D
apply the voltage with a slow ramp!
(2) Connect L and N together as well as all
Output
output poles.
C
+
(3) Use only AC test-voltages with 50/60Hz.
-
The output voltage is floating and has no ohmic
reference to ground.
A
Type Test
60s
2500Vac
Factory Test
5s
2500Vac
Field Test
5s
2000Vac
The unit is designed to support loads with a higher short-term
power requirement without damage or shutdown.
for 4s
continuous
Output Current
5A
10A
15A
20A
25A
Bonus time
Duration until the output starts dipping. The
bonus time is hardware controlled.
P
T
T
PEAK
PEAK
0
P
0
Overload, no-load, short-circuit proof
IP 20
I
2
yes
yes
III
>3.5mm
T6A3, Device protection, not externally accessible
B
C
D
3000Vac
500Vac
500Vac
2500Vac
500Vac
500Vac
2000Vac
500Vac
500Vac
10s
8s
max.
6s
4s
min.
2s
Output Current
0s
110% 120% 130% 140% 150% 160%
Examples for pulse load
compatibility:
P
P
T
T
PEAK
0
PEAK
0
360W
240W
1s
>25s
360W
0W
1s
>1.3s
360W
120W
0.1s
>0.16s
360W
120W
1s
>1.6s
t
360W
120W
3s
>4.9s
t
EN/IEC 60529
PE (Ground) connection required!
EN 50178, not conductive
Output shut-down with automatic restart
Output shut-down with automatic restart
EN 50178
e.g. screws, small parts ...