power the siren with the power supply in the package and turn on the
power switch (red). The built-in buzzer will sound twice and the indicator
light will flash twice.
b. Wireless or wired working mode (Optional for certain models)
When the jumper is inserted in the "NO" position, this product is used as
a wired siren.
When the jumper is inserted in the "NC" position, this product is used as
a wireless siren.
Notes: only when the siren is in the wireless mode you can code remote
controllers, learn detectors and pair to an alarm system in wireless mode.
With wired mode selected, remote controller and detector do not work
anymore, and the siren would make sounds once connected to the
power.
c. Stand-alone working mode
The siren can work independently as an alarm system, with remote
controller and detectors paired to it. In this mode, the remote control
and the detectors have to be coded with a standalone siren to trigger the
siren to make alarms.
d. Coding of remote controllers & wireless detectors
In arm or disarm state, keep pressing the alarm set key, until it rings once
with indicator light flashing once, release the set key, then the alarm
lights flash quickly, waiting for the wireless signal from remote controller
or detector press SOS key of the remote controller or trigger detector
(which needs coding) to launch a wireless signal it means the coding
process is successful when you hear the siren releases two alert tones
confirming it has received the signal. If you want to learn the next remote
controller or detector, only trigger the remote or the detector again. If the
alarm does receive any signal within 10 seconds, it will exit the pairing
mode automatically.
Operation method: keep pressing [set] key of standalone siren, until it
sounds once with indicator light flashing once.