Water connection
Pressurized system
The filling pipe needs to be kept away from or insulated against sources of
intense heat such as heating, refrigerator burners, etc.
- Get as close as possible to the pressurized water branch of the vehicle.
- Fit the stopcock somewhere that is easily reached.
Intercept the pressurized cold water pipe of the vehicle and fit a union "T" complete
-
with pipe and connector to insert at the inlet of the stopcock.
Important: for this job, only use original pipes and fittings for the vehicle (not
provided).
To fit the stopcock:
- Use liquid Teflon to seal the fitting.
- Fit the metal clip to the pipe.
- Fit the stopcock somewhere that is easily reached.
Date 11.09.2020
Non-pressurized system
To make this type of system you have to use bipolar black cable that descends
from the unit.
- Fit a 12 Volt, 3-way relay to control the pump.
- Connect the white wire (constant positive).
- Connect the black wire (negative).
- Intercept the two wires coming out of the microswitch under the cock and connect
them to the relay.
SYSTEM TO CONNECT IN CASE OF
6
COCK MICRO
IMMERSION PUMP.
USE THE VEHICLE'S ORIGINAL PUMP CONTROL WIRES;
NEVER TAKE POWER DIRECTLY FROM THE PUMP.