Note: all the receivers within range when the channel button is pressed (and
which have at least one of the transmitter channel buttons memorised) will
activate their signal buzzer "B1" (fig. 10).
2. Press one of the channel buttons on the same transmitter. The receivers
which do not contain that channel code will sound a five-second long
"beep" and will then deactivate. The receivers which contain the channel
code will sound a one-second long "beep" and will enter the "program-
ming via radio" mode.
3. Press the previously chosen channel buttons on the transmitter which you
wish to memorise; the receiver will sound 2 "beeps" of half a second each
after which the receiver will be ready to receive another code.
4. To leave the programming mode wait for 3 seconds without pressing any
buttons. The receiver will sound a five-second long "beep" and will then
exit the programming mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid
"beeps" and will automatically leave the "programming via radio" mode.
The same signal is given each time you try to enter "programming via radio"
when the memory is full.
Note: the memo radio procedure can only be carried out after program-
ming has terminated and you have quit the setting/programming
Memorizing more transmitters by using a previously memorised
transmitter (only S504 - S508)
This procedure allows you to enable a new transmitter (from a remote po-
sition) with the help of a transmitter that has already been memorised in
the system. As the presence of the receiver is not required this procedure
can be carried out in any remote location (for example in your chosen sales
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
outlet).
Access to the "rapid memorizing" procedure is possible if the "MEMO RA-
DIO" function has been activated via the menu "OPTIONS" on the electronic
programmer.
- Remove the upper cover from the transmitter to be memorised and from
the transmitter that has already been memorised as shown in the drawing
below (det. a).
- Place the transmitter A, that has already been memorised in the receiver,
beside the new transmitter B (det. b).
- Using a pointed object press and release the MR button on both transmit-
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
ter (in sequence or simultaneously).
- The orange LEDS on the transmitters will flash slowly.
- Press and release a channel button on transmitter A that is already pre-
sent in the receiver (det. c).
- The led of the new unit B will remain lit for 3 seconds to confirm memoriza-
tion (det. d).
Transmitter B will now command the receiver exactly like transmitter A.
1
A
CONNECTING THE ANTENNA
Connect an ANS400 / ANQ800-1 tuned antenna using a coaxial cable RG58
(impedance 50Ω) with a maximum length of 15 m.
Description :
Drawing number :
DM0910
FUNCTION MODES
Product Code :
TRQ504
Draft :
P.J.Heath
Date :
29-10-2013
1) Automatic
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Selected by enabling automatic reclosing (Automatic reclosing "ON" on
the display). When the gate is completely closed the opening command will
start a complete cycle which will end with automatic reclosing.
Drawing number :
Description :
Drawing number :
DM0911
Automatic reclosing starts after the programmed pause period has elapsed
Product Code :
Product Code :
TXQ504C4
(minimum 2 seconds) when the opening cycle has been completed or
Draft :
Date :
Draft :
P.J.Heath
29-10-2013
straight away after the intervention of a photoelectric cell (the intervention
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
of a photoelectric cell causes the pause time to be reset).
MR
A
B
B
MEMORIZZAZIONE CODICE TX-TX
Description :
MEMORIZZAZIONE CODICE TX-TX
DM0912
MEMORIZZAZIONE CODICE TX-TX
TXQ504C4
P.J.Heath
Date :
29-10-2013
During the pause time "Pause" will flash on the display along with the
remaining pause time.
Pressing the blocking button during this period will stop automatic reclosing
and consequently stop the display from flashing.
The indicator light remains lit until the closing manoeuvre has terminated.
2) Semiautomatic
Selected by deactivating automatic reclosing (Automatic reclosing "OFF"
on the display). Work cycle control using separate opening and closing
commands.
When the door has reached the completely open position the system will
wait until it receives a closing command either via an external control button
or via radio control, before completing the cycle.
The indicator light remains lit until the closing manoeuvre has terminated.
3) Manual manoeuvring with released motors
Releasing the motor the gate can be moved by hand; once the motor has
been re-engaged the programmer will recover the position after two con-
secutive attempts to arrive at the travel limit.
4) Emergency manoeuvre
menu.t
By default the emergency manoeuvre is disabled, to enable it move the
jumper to the position J6 "ENABLE" (fig. 10).
If the electronic programmer no longer responds to commands due to a
malfunction you may use the EMRG1 or EMRG2 inputs to move the gate
leaf manually (fig. 10).
The EMRG1 or EMRG2 inputs directly command the motor without pass-
ing through the logic control.
Gate movement will be at normal speed and the direction depends on the
installed position of the motor:
Attention! During the emergency manoeuvre all safety devices
are disabled and there is no gate positioning control: release the
commands before you are at the mechanical travel buffer. Only
use the emergency manoeuvre in cases of extreme necessity.
The electric lock (even if it is enabled) is not active. Therefore
if an electric lock is fitted it will have to be activated manually.
After you have carried out an emergency manoeuvre the electronic program-
mer will lose the position of the gate ("out of pos" on the display) and therefore
when normal operation is restored it will carry out a repositioning manoeuvre.
LIMITED OPENING (PEDESTRIAN ACCESS)
This always effects gate 1; the limited opening space can be set (see
display menu) to 1/3, half, 2/3 or the entire opening distance for gate 1.
• If the "open-close" mode is set for the "TD" button (menu "OPTION")
activating the "TAL" button will start the limited opening stage (only from
the completely closed position) but while the gate is opening pressing
the button again will have no effect. Once the opening position has
MR
been reached pressing the "TAL" button will start closing after which
pressing "TAL" again will have no effect.
• If the "open-block-close" mode is set for the "TD" button (menu
"OPTION") activating the "TAL" button will start the limited opening
stage (only from the completely closed position) pressing the button
again will block the gate; pressing the button a third time will start the
closing cycle. Pressing the "TAL" button again will have no effect.
• If an opening command is received during limited opening; the limited
opening command will become a full opening command.
If the FI photocell cuts in during the closing stage you will only have
partial movement in the opening direction (It reopens only for the dis-
tance it has been closing the gate).
• Note: The limited opening command can also be given by remote control.
COURTESY LIGHT /CH2 RADIO OUTPUT
Binding posts "9 ","10 " are linked to a C-NO relay; this can be activated
as follows:
• Jumper J5 in position 1:
the contact is closed by a timer and works as a "courtesy light"
• Jumper J5 in position 2:
the contact works as a second radio channel.
Binding posts "9 ","10" only give a potential free contact; this means that the
courtesy light will have to be powered by an external circuit and the contact
used as a simple switch.
21