4
FUNCTION AND OPERATION
Installation position and location of the light is important: Ensure the light is mounted straight on the wall, otherwise, the induction distance
may be limited.
When the light works at a height of 6.5 feet and temperature of 77 degrees Fahrenheit, the light would provide a maximum induction dis-
tance of 40 feet and 180 degrees of induction range.
The sensor is more sensitive in passing across the light than going towards it.
Note: Working temperature of all the functions is -7°F ~95°F.
Time and Sensitivity setting:
TIME: Lighting time of the light. Use a slotted screwdriver, turn clockwise to increase, and counterclockwise to reduce, every quarter increases
about 60 seconds. Setting range is 20-180 seconds.
SENS: Sensitivity, induction distance of the light. Use a screwdriver, turn clockwise to increase, and counterclockwise to reduce. Default setting
induction distance is 10 meters.
Mode:
AUTO:
During the daytime, it is off. At dusk, when human activity is sensed, the light turns on at high brightness (100%). When human activity is
NOT sensed (stationary or left), the light stays on for 20-180 seconds (as set TIME) then turns off. The default setting of lighting time is 60
seconds.
LOW LEVEL: NOT functional at this mode.
PC:
During the daytime, it is off. The light turns on at dusk. Other settings are NOT functional at this mode.
AUTO+:
Note: Incandescent or dimmable LED bulbs must be used in this mode.
During the daytime, it is off. At dusk, the light turns and keeps staying on at low brightness (0%-50%, as setting of LOW LEVEL). When
human activity is sensed, the light turns to high brightness (100%). When human activity is NOT sensed (stationary or left), the light keeps
high brightness for 60 seconds then turns back to low brightness.
LOW LEVEL: Low brightness of the light. Use a slotted screwdriver, turn clockwise to increase, and counterclockwise to reduce. Setting
range is 0%-50% brightness.
6'~10'
5'~40'
Motion
Motion
Sensor
Control panel
P. 9