Model:
Power Supply
Heating capacity (air in
7°C, 85% R.H., Condenser
water in/out 30/35°C)
Heating capacity (air in
7°C, 85% R.H., Condenser
water in/out 40/45°C)
Heating capacity (air in
7°C, 85% R.H., Condenser
water in/out 47/55°C )
Cooling capacity (air in
35°C. Evaporator water
in/out 23/18°C )
Cooling capacity ( air in
35°C. Evaporator water
in/out 12/7°C)
ERP Level ( Outlet water temp. at 35 ℃)
ERP Level ( Outlet water temp. at 55 ℃)
MAX. input power
MAX. input current
Refrigerant / Weight(kg)
Rated water flow
Specification
V/Ph/Hz
Heating Capacity
kW
Power Input
kW
COP
W/W
SCOP
Heating Capacity
kW
Power Input
kW
COP
W/W
SCOP
Heating Capacity
kW
Power Input
kW
COP
W/W
SCOP
Cooling Capacity
kW
Power Input
kW
EER
W/W
SEER
Cooling Capacity
kW
Power Input
kW
EER
W/W
SEER
/
/
kW
A
/
m³/h
AURUM-AT90M
AURUM-AT150M
220~240/1/50
220~240/1/50
9.67
1.92
5.03
4.87
9.41
2.27
4.15
4.36
9.15
2.57
3.56
3.85
7.44
1.79
4.15
7.45
6.14
1.83
3.35
4.98
A+++
A+++
3.00
13.50
R290/0.55
1.00
52
AURUM-AT220T
380~415/3/50
16.85
23.06
3.36
4.63
5.01
4.98
4.85
4.83
15.24
22.72
3.71
5.60
4.11
4.06
4.35
4.35
15.06
22.40
4.28
6.38
3.52
3.51
3.84
3.86
13.74
18.86
3.34
4.74
4.11
3.98
7.23
7.05
10.43
16.40
3.17
5.09
3.29
3.22
4.82
4.71
A+++
A+++
A+++
A+++
5.50
9.00
24.50
16.00
R290/0.9
R290/1.4
1.80
3.00
V.1

Publicidad

loading

Este manual también es adecuado para: