3. Operating instructions
3.1. Starting instructions
I
Install battery on tool, check battery power on power indication :
During tool operation, press the button on power indication and the remaining power is shown.
I
Choose correct nose piece and fit it onto the tool (See §2)
I
Ensure that vent holes on the tool body are not covered or obstructed.
I
Ensure that the mandrel collector is installed onto the tool.
3.2. Operating instruction
I
Insert the rivet mandrel fully into the nose piece, install it onto the work piece, start the operation
by depressing the trigger.
I
After the rivet is set, release the trigger and the jaw assembly of the tool returns to the start position
automatically.
I
Eject the rest mandrel by tilting to the rear into the mandrel collector, or to the front through the nose piece;
I
The tool is equipped with overload protection. In the event of an overload, the operation will be
stopped and the warning light shows. Release the trigger and the jaw assembly will return to the
start position.
4. Trouble Shooting
4.1. Blind rivet cannot be set
When depressing the trigger, 4 LED power indication lights blink in
rotation, indicating low power
Battery damaged
Jaw assembly loose
4.2. No rest mandrel discharge
Wrong nose piece
Nose piece worn
Rest mandrel jammed in clamps
Mandrel collector full
Mandrel release tube blocked
4.3. Warning light indicates faults
Clamps not return to the start position
Overloading
Overheating
Battery empty
NOTE: in case of remedy measures do not work as described above, the tool has to be repaired by skilled
personnel or to be returned to the distributor or manufacturer's agent.
Heruntergeladen von
manualslib.de
28/04/14
LED Light on
4 x
3 x
2 x
1 x
Troubles and causes
Troubles and causes
Troubles and causes
Handbücher-Suchmachiene
18:12
Page 17
Power remaining
95% ±5%
75% ±5%
50% ±5%
25% ±5% –> Charging battery is recommended
Charge battery
Change battery
Tighten the assembly
Change to correct nose piece
Replace nose piece
Loosen the mandrel, clean the clamps assembly and lubricate them
Discharge the mandrel collector and empty
Remove the mandrel and check for ejection
Release the trigger
Check the rivet as per tool working capacity
Cool off the tool in the air
Charge the battery, or replace when needed
Remedy
Remedy
Remedy
15