Safety
2.4
Comfort for employing and safety functioning. The electronic digital control panel order
•
the combined action of combusted gas fan, combustible feed, convection fan and
environment temperature control. This control system guarantee the best conditions for
combustion and functioning, reducing to the minimum the exercise cost.
The best efficiency with minimal emission. The wide surface of thermical exchange,
•
with the best air combustion control, has the best combustible exploitation as result.
The measured out pellet loading in the foyer allows a complete combustion with the
lower toxic values into the exhaust gas.
AUTOMATIC SAFETY FUNCTION
Voltage drop. Even after a brief voltage drop, the unit stops and then restarts, resuming
•
the normal operation or restarting the automatic ignition phase, without any security risk.
Shutdown due to overheating. In the event of abnormal heating of the appliance, the
•
security system intervenes and switch off the stove. The stove can then be switched on
again after leaving it to cool for at least 45 minutes. The persistence of this condition
must be verified by the service center or qualified personnel
Low-temperature shutdown. If the temperature of the appliance drops down to a
•
certain value, the unit turns off (for example the finishing of the fuel). This can also be
switch off can also accur if the lighting phase takes to much time. The stove must then
be re switched on again The persistence of this condition must be verified by the service
center or qualified personnel.
Electrical surge protection device. The appliance is protected against overcurrent by a
•
fuse (see technical data) placed: one on the electronic board and one on the power socket.
For its replacement, contact Technical Service
RESIDUAL RISKS
The stove does not present itself potential risks, although it is complete with coatings in all its
parts, nevertheless the following residual risks may be present:
Risk of burns
Between the back of the stove and the smoke outlet (fume outlet pipe).
•
Contact with glass
•
Electric risk
Alimentation cable
•
Motors connection
•
Risk of fire
Opening the front door when the ashes are not extinguished.
•
Risk of cutting
Between the auger shaft and the material loading conduit; in the event of a jam, do not
•
carry out any material removal operations unless the stove has been switched off and the
power supply disconnected.