HYDRAULIC CONNECTION
Water quality necessary for this device: NF-EN-16713-3
The HP is compatible with all types of water treatment. The HP must imperatively be connected by a PVC pipe of Ø 50mm to the swimming pool's hydraulic
Circuit, after the filter and before the treatment system, regardless of its type (Cl, pH, Br metering pumps and/or electrolyzer).
Follow the hydraulic connection order (blue = water in, red = water out)
A bypass must be installed to facilitate work on the HP.
Before connecting the PVC pipes to the HP, make sure the circuit is clean of any work residue (stone, soil, etc.).
Connection of the condensate evacuation pack:
During operations, the HP is subject to a condensation phenomenon. This translates into a water flow, which can be more or less important depending on the
degree of humidity. To channel this flow, which can represent several litres of water per day, we recommend you install the provided condensate evacuation
pack and connect it to a suitable water evacuation circuit.
Provided connections
(ø 50mm)
Evacuation of the condensate
ELECTRICAL CONNECTION
Connection of the power supply:
prior to undertaking any intervention inside the HP, it is imperative to disconnect the power supply from the HP; there is a risk of electrocution that can cause
damages, severe injuries and even death.
Only a certified and experienced technician is authorised to conduct cabling work in an HP or to replace the power cable.
the power supply should match the voltage featuring on the information plate of the HP.
The HP must be connected to an earthing connection.
Electrical Installation:
To ensure safe operations and to protect the integrity of your electric installation, the HP should be connected to the electrical mains according to the following
rules:
Upstream, the electrical mains should be protected by a 30-mA differential switch.
The HP should be connected to a suitable class C circuit-breaker (see the table below) according to the standards and regulations in force in the country
where the system is installed.
It is recommended to crimp the electric cables on lugs adapted to the diameter of the cable chosen before connecting them to the HP
The power cord should be adapted to the power of the HP and the length of cable required for the installation (see the table below). The cable must be suit-
able for outdoor use.
In the case of a three-phase system, it is imperative to follow the connection order of the phases. If phases are inverted, the compressor of the HP will not
work.
In public spaces, the installation of an emergency stop button close to the HP is mandatory. The voltage must match the voltage mentioned on the HP.
The connections must be sized based on the power of the HP and on the installation state.
By-pass
Open Valve
Half-open valve
Closed valve
- 21 -
Water treatment (disinfection, pH correction)
Bypass valve
located after the HP
(adjustment)
From the swimming pool
Toward the swimming