RELAY OUTPUT
•
Function: select the command which activates the Relay output for the audio/video module
◊
Lock-release: every lock-release command activates the output
◊
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
◊
Call sent: every call sent activates the output
•
Activation
◊
Local output control (non-editable)
•
Output
◊
Relay (non-editable)
•
Enable Tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
VIRTUAL OUTPUT 1 / VIRTUAL OUTPUT 2
•
Function: select the command which activates the virtual output for the audio/video module. The virtual
outputs are NOT physically part of the module, they are commands sent over the bus.
◊
Lock-release: every lock-release command activates the output
◊
Actuator control: every actuator command with the address set in the "Address sent by external
unit" field activates the output
◊
Call sent: every call sent activates the output
•
Activation
◊
Local output control: activates the output set in the "Output" field (SE output for the module or Relay
output for the module)
◊
Control on Ultra bus (UDB): the command activates the relay on the Module keypad specified in the
"Type" field (Output: Relay 1 or Relay 2)
◊
Actuator control: the command activates the actuator with the address entered in the "Address" field
•
Enable tones: a confirmation tone is emitted when the output is activated for the time period set in the
"Activation time (sec.)" field
EVENTS
You can set the several functions to be executed when specific events occur. Up to 20 events can be set.
EVENTS
•
No.: select the progressive number of the event
•
Action: select the action triggering the event
◊
None: no action (default)
◊
Self activation: if a door entry monitor with an address that falls within the values entered in the "From
address" and "To address" fields performs a self activation, it triggers the event specified in the
"Activation" field
◊
Call sent: if a call is sent to a door entry monitor with an address that falls within the values entered in
the "From address" and "To address" fields, it triggers the event specified in the "Activation" field
◊
Lock-release: if a lock-release command is sent from a door entry monitor with an address that falls
within the values entered in the "From address" and "To address" fields, it triggers the event specified
in the "Activation" field
◊
Actuator control: if an actuator command is sent with an address that falls within the values entered in
the "From address" and "To address" fields, it triggers the event specified in the "Activation" field
•
Activation: action triggered after the event specified in the "Action" field occurs
◊
Local output control: activates the output set in the "Output" field (SE output for the module or Relay
output for the module). NOTE: Module SE Output and/or module Relay Output must be set in the menu
"Outputs" > SE Output and/or Relay Output with "Function" > Lock-release and/or actuator
◊
Control on Ultra bus (UDB): activates the relay on the number keypad specified in the "Type" field
(Relay 1 or Relay 2)
◊
Actuator control: activates the actuator with the address specified in the "Actuator address" field
(from 1 to 255)