Emptying and cleaning the inside of the boiler tank
ATTENTION: Clean the boiler at least once a month to remove all limescale residues that could jeopardize
the proper operation of the appliance.
ATTENTION: Switch the appliance off, unplug it and allow it to cool down before proceeding with the
boiler cleaning to prevent injuries.
•
Exhaust the residual pressure inside the boiler (I), by pressing the steam push button (A) on the gun (C) and directing
the jet into an appropriate container.
•
Screw the safety cap (L) slowly and remove it.
•
Fill the boiler (I) slowly with tap water to prevent any steam puff. Shake the appliance vigorously and turn it upside down
to empty. Repeat the above procedure several times.
ATTENTION: Never add limescale removers, vinegar or other perfumed substances into the boiler to prevent
the risk of damage of the unit and will immediately void the warranty.
PROBLEM
The nozzle
does not dispense steam
The nozzle
dispenses little steam
CLEANING AND MAINTENANCE
TROUBLESHOOTING...
CHECK
Steam ready light (F) on
Steam ready light (F) off
Steam ready light (F)
off – Water in the boiler (I)
Steam ready light (F) off
POSSIBLE CAUSES
Cold boiler tank
No water in the boiler
tank (I)
Malfunction
Cold boiler tank
- 15 -
EN
I T
POSSIBLE REMEDY
Wait for the steam ready
light (F) to switch off
Refill the tank, as descri-
bed in the paragraph
"INSTRUCTIONS FOR
USE"
Contact an ASSISTANCE
CENTRE
Wait for the boiler tank (I)
to heat up