Read the assembly instructions carefully before starting assembly.
Electrical connections
The electrical installation of the stove must be carried out by a professional and sized
according to the power of the stove. The stove is thus connected with its own electric line,
not supplied as it depends on your installation.
This installation must be planned before mounting the cabin.
The entire internal electrical installation of the sauna (lights, LEDs, etc.) is connected direct-
ly to the electric stove, the electric cables being pre-wired within the cabin.
Electrical sizing:
Power of
the stove
volume
(kW)
4,5
3
6
5
8
7
9
8
Electrical connection for Har-
via Vega stove
7
INSTALLATION
Sauna
230V 1N
(m3)
6
3 x 2,5
8
3 x 2,5
12
3 x 6
14
3 x 10
Electrical connection
Fuse
400V 3N
1 x 20
1 x 35
1 x 35
1 x 50
400 V/
1 2 3 4 5 6 7
415 V
3N~
GRD
N
COMMANDE DU CHAUFFAGE ÉLECTRIQUE
REGELEN VAN ELEKTRISCHE VERWARMING
230 V/
1 2 3 4 5 6
240 V
3~
GRD
L1
L2
230 V/
1 2 3 4 5 6
240 V
1N~
GRD
N
Fuse
5 x 1,5
3 x 10
5 x 1,5
3 x 10
5 x 2,5
3 x 16
5 x 2,5
3 x 16
b0
b
a1
a
b0
b
a1
a
b0
b
a1
a
L1 L2 L3
P
L3
L1