Descargar Imprimir esta página

Lacme Clos 2000-1 Instrucciones De Empleo página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Classic schema : all devices
Schema example + reduced power :
Reduced power : allows for example to make pens for animals in a state of temporary weakness (after calving, ... etc.)
or susceptible animals while maintaining other enclosures at maximum power.
Example of a loop connection :
When one end of the fence is connected to terminal 3 of the unit, the LED B allows to monitor the proper functioning of
this fence.
In this configuration :
- if the green LED (B) lights, the loop is correct (a circuit is achieved)
-If the green indicator (B) is not lit, the wire is cut.
In this case the two segments of the connexion the outward pulses remain electrified.
But that of the return to the energiser remains at a reduced power.
Clos 2000-4 Led / Clos 2000-6 Led / Clos 2000-6 D
wire connected to
« full output terminal »
wire connected to
« reduced output terminal »
Clos 2000-4 Led / Clos 2000-6 Led / Clos 2000-6 D
B
3
3
insulator
insulator
insulator
insulator
Fence wire connected to the "HIGH OUTPUT
POWER "
and then looped
to the terminal reduced output
7
insulator
insulator
insulator
insulator

Publicidad

loading

Productos relacionados para Lacme Clos 2000-1