Descargar Imprimir esta página

CESVA LRS-03 Manual Del Usuario página 31

Limitador registrador sonométrico

Publicidad

Idiomas disponibles

Idiomas disponibles

LRS-03
User's manual
 Maximum "slow" level measured in the interval; together with the number of
seconds that the "slow" level has exceeded the programmed limit in the interval
 Maximum "fast" level measured in the interval; together with the number of
seconds that the "fast" level has exceeded the programmed limit in the interval
 The percentiles obtained in the interval: L1, L5, L10, L50 and L90. A percentile Lx
shows the sound pressure level that has been exceeded during x % of the time
that the interval lasts.
13/09/99
13/09/99
23:00 < --> 23:03
Leq :
80.3 dBA
Limit Leq:
85 dBA
LS max :
83.2 dBA
Exceed.: 0
>85 dBA
LF max :
87.0 dBA
Exceed.: 16
>85 dBA
SESSION RECORDS: These allow you to consult all the session records stored in the
-
LRS-03. The session records contain the following information:
 Date and time of the beginning of the session
 Date and time of the end of the session
 Equivalent continuous level of the session
 Maximum allowed equivalent continuous level during daytime
 Night timetable
 Maximum allowed equivalent continuous level at night
 Length of time that the LRS-03 penalises with a 6 dB attenuation (Attenuation
time)
 Time in seconds that the LRS-03 has been disconnected form the main supply
during the session (Disconnection).
 Time expressed in seconds that the LRS-03 has attenuated 60 dB and the
measured sound pressure level has continued exceeding the programmed limit
during the session (Limit exceeded)
 Time in seconds that the sensor has been manipulated during the session
(Sensor inact.).
 Level, date and time of the maximum 1 min. Leq measurement obtained in the
session
 Level, date and time of the minimum 1 min. Leq measurement obtained in the
session
 Maximum "slow" level measured in the session; together with the number of
seconds that the "slow" level has exceeded the programmed limit in the session
 Maximum "fast" level measured in the session; together with the number of
seconds that the "fast" level has exceeded the programmed limit in the session
 The percentiles obtained in the session: L1, L5, L10, L50 and L90. A percentile Lx
shows the sound pressure level that has been exceeded during x % of the time
that the interval lasts.
MaxLeq1':
81.1 dBA
13/09/99
23:01
MinLeq1':
UND dBA
13/09/99
23:02
Percentiles (dBA )
L1
: 86.5
L50: 80.0
L5
: 85.0
L90: UND
L10 : 80.5
29
Disconnection:
0 s
Limit ex cede : 0 s
Sensor inact. : 0 s
Printer error :
No

Publicidad

loading