9 ) M I N T M
1 0 ) M A X T M : 1 0 , 0 s
9) Min time
It is possible to set a time range. Within this range, the
screw is OK. Minimum time is 0 second (OFF).
Use:
- Press OK on Min Time
- Select through UP/DOWN buttons.
- Press OK to confirm or ESC to quit without saving
9 ) M I N T M
1 0 ) M A X T M : 1 0 , 0 s
10) Max time
It is possible to set max time from Min time + 0.1 second
to 10.0 seconds. Over the max time, screwdriver will be
automatically stopped.
Use:
- Press OK on Max Time
- Select through UP/DOWN buttons.
- Press OK to confirm or ESC to quit without saving
1 1 ) P A S S W O R D S E T
1 2 ) P A S S W O N : Y E S
11) Password set
It is possible to set a password of 4 digits. The password is
required to enter the menu anytime you switch on the unit.
Without the password, it is not possible to change any
parameter. With clutch model, the operator can modify the
torque (it is mechanically set in the screwdriver), but with
ECL model no parameters can be changed.
Default password is '0000'.
Use:
- Press OK on Password Set
- Set through UP/DOWN the digit
- Press OK to confirm.
- Repeat for all the digits.
1 1 ) P A S S W O R D S E T
1 2 ) P A S S W O N : Y E S
12) Password On
It is possible to choose if the password may or may not be
required.
Use:
- Press OK on PASSW ON
- Select through UP/DOWN buttons.
- Press OK to confirm, ESC to quit without saving
1 3 ) L A N G U A G E : E N
13) Language
To select between 3 languages: English, German and
Italian.
: 0 , 0 s
: 0 , 0 s
Use:
- Press OK on Language
- Select through UP/DOWN buttons.
- Press OK to confirm, ESC to quit without saving
OTHER FUNCTION:
Display backlight: to reduce the consumption of unit, over
60 second after last operation backlight will be turn OFF. To
active again you may press a taste (OK, ESC, UP, DOWN) or
LEVER on screw driver or external command on the rear of
unit.
ECL model calibration:
The ECL model requires a calibration.
Screwdriver with clutch doesn't need it.
For any details, see the WBTS instructions manual.
ATTENTION:
The process required that the screw driver is free of load,
don't connect something, take the screw driver free on
hair.
If you connect for first time a ECL model to unit is
necessary to do this procedure.
- Turn ON unit and set ECL model to point 1) of menu
(see chapter Menu for more details)
- Now set torque to LOW to point 3) and press OK to save
(see chapter Menu for more details),
be attention to set point 4) to soft, hard mode don't
accept Torque range
- Turn OFF instruments
- Press lever and hold. With lever press turn ON unit
after 1 second system automatically calibrate unit with
screw driver.
- Now repeated process but with Torque range set High.
- Calibration is finished
English