Descargar Imprimir esta página

Kärcher WPD 50 Ws Manual Del Usuario página 15

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Fault
The device shows "Ready for use" but
does not dispense water. All buttons
are illuminated.
The device is not working. The but-
tons do not light up.
The dispensed water is not cooled,
even though the "Chilled water" but-
ton was pressed
The carbonated water and cold water
buttons light up alternately and a sig-
nal tone can be heard.
The carbonated water button no
longer lights up after 60 seconds and
the dispensing of carbonated water is
blocked.
Internal pump starts when dispensing
"CO
chilled water" with different de-
2
lays.
Internal pump starts up briefly at reg-
ular intervals
No carbonation in the water.
Too little carbonation in the water
Splashing delivery of carbonated wa-
ter for larger quantities
Warranty
The warranty conditions issued by our sales company
responsible apply in all countries. We shall remedy pos-
Device performance data
Working voltage of the battery
Power frequency
Power protection (slow-blowing)
Max. power input
Water supply pressure
Water supply temperature
Pressure adjustment range for CO
Ambient temperature
Water dispenser (depending on supply pressure and filter status)
Chilled water
CO
Carbonated water
2
Min. temperature of chilled water
Dimensions and weights
Width
Depth
Height
Weight
Subject to technical modifications.
Time & date
Performed
Daily
Remove and clean the drip tray.
After an overnight device standstill, dispense 0.5 l of each type of water and dispose of it.
Weekly, more often if neces-
Clean the outside of the device, clean the drip tray with hot water or in a dishwasher.
sary
Do not use cleaning agents containing alcohol, acidic components or scouring agents for cleaning plastic surfaces.
Half-yearly
If the water quality is bad, replace the Hy-Pure-Plus filter.
Perform chemical cleaning, see chapter Chemical cleaning.
Annually
Replace Hy-Pure-Plus filter.
The decisive factor for the filter change interval is the amount of water dispensed and the water quality of the inlet water.
Troubleshooting guide
Cause
The water supply is interrupted.
The power supply is faulty.
The fuse is defective.
The cooling module has not reached its nominal tem-
perature.
Temperature regulation fault.
Refilling of the carbonator tank failed.
This is a normal function, not an error.
This is a normal function for the function of the carbon-
ator tank.
CO
gas pressure too low.
2
CO
bottle or CO
cylinder empty.
2
2
The cold water tank has not reached its nominal tem-
perature.
The filter is dirty and reduces the necessary water flow. 1. Check the flow of the filter and replace the filter if necessary.
CO
bottle or CO
cylinder almost empty.
2
2
Refilling of the carbonator tank is impaired.
The gas pressure setting is too high.
sible malfunctions on your device within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
2
Rectification
1. Ensure a correct water supply.
2. Check the shut-off devices.
3. If the fault persists, contact the service department.
 Check the power supply.
 Remove the cover of the fuse next to the device switch, replace the
fuse. If the fuse blows again, switch off the device, contact the service
department.
1. Wait 20 to 40 minutes and check it again.
If the cooling function exhibits permanent failure:
2. Switch off the device.
3. Contact the service department.
 Contact the service department.
1. Switch off the device.
2. Check the water supply inlet.
3. Check the gas pressure.
4. Switch the device off and back on again.
5. If the fault persists, contact the service department.
 No fix necessary
 No fix necessary
 Correct the CO
1. Replace the CO
2. If the fault persists, contact the service department.
 Check the carbonation in the water again after waiting 20 minutes.
2. If the fault persists, contact the service department.
 Replace the CO
 Check the flow of the filter and replace the filter if necessary.
1. Correct the CO
2. If the fault persists, contact the service department.
Technical data
Maintenance plan
English
gas pressure.
2
bottle or the CO
cylinder.
2
2
bottle or the CO
cylinder.
2
2
gas pressure.
2
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
WPD 50 Ws
V
220-240
Hz
50
A
6
W
200
MPa
0,15 -0,6 (1,5-6)
(bar)
°C
5-30
MPa
0,38...0,42 (3,8...4,2)
(bar)
°C
5 - 32
l/h
120
l/h
80
°C
6
mm
300
mm
440
mm
395
kg
19
15

Publicidad

loading