Installation
GB
! Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
! Please keep these operating instructions for future reference.
Pass them on to possible new owners of the appliance.
Positioning
! Keep packaging material out of the reach of children. It can
become a choking or suffocation hazard (see Precautions
and tips).
! The appliance must be installed by a qualified professional
according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.
! This unit may be installed and used only in permanently
ventilated rooms in accordance with current national
regulations.The following requirements must be observed:
• The room must be equipped with an air extraction system
that expels any combustion fumes. This may consist of
a hood or an electric fan that automatically starts each
time the appliance is switched on.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
• The room must also allow proper air circulation, as air is
needed for combustion to occur normally. The flow of air
must not be less than 2 m
A
Examples of
ventilation holes
for comburant air.
Adjacent
Room to be
Room
Vented
Enlarging the ventilation slot
between window and floor.
• Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in
the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or stored
in rooms or storage areas that are below ground level
24
Directly to
the Outside
/h per kW of installed power.
3
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm
the opening must not be vulnerable
to any type of blockages.
The system can also provide the air
needed for combustion indirectly,
i.e. from adjacent rooms fitted with
air circulation tubes as described
above. However, these rooms must
not be communal rooms, bedrooms
or rooms that may present a fire
hazard.
(cellars, etc.). It is advisable to keep only the cylinder
being used in the room, positioned so that it is not subject
to heat produced by external sources (ovens, fireplaces,
stoves, etc. ) which could raise the temperature of the
cylinder above 50°C.
Fitting the appliance
The following precautions must be taken when installing
the hob:
• Kitchen cabinets adjacent to the appliance and taller than
the top of the hob must be at least 600 mm from the edge
of the hob.
• Hoods must be installed according to their relative
installation instruction manuals and at a minimum
distance of 650 mm from the hob (see figure).
• Place the wall cabinets adjacent to the hood at a minimum
height of 420 mm from the hob (see figure).
600mm min.
• The installation cavity should have the dimensions
indicated in the figure. Fastening hooks are provided,
allowing you to fasten the hob to tops that are between 20
and 40 mm thick. To ensure the hob is securely fastened
to the top, we recommend you use all the hooks provided.
55
mm
• Before fastening the cooktop in place, position the seal
(supplied) along the perimeter of the countertop, as
shown in the figure.
;
2
Hook fastening diagram
Hooking position
for top H=20mm
If the hob is installed beneath a wall
cabinet, the latter must be situated
at a minimum of 700 mm above
the hob.
555
mm
Hooking position
for top H=30mm