CROUZET SOLID STATE RELAYS - PANEL MOUNT PRODUCTS have been developed to offer all the advantages of electronic switching technology. The 44.8 mm
hockey puck industrial housing is quick to install. The product is compact and reliable. Please refer to the data sheet available on www.crouzet.com
GN2
MOUNTING INSTRUCTIONS
ON HEATSINK
5
1
3
4
M4 x 12 mm / 1.2 Nm mini
1.
Select the adequate heatsink (see thermal curves on product datasheet).
2.
Use thermal pad or thermal grease between the SSR and heatsink
(0.06 mm of thickness).
3.
Open the removable cover.
4.
Two screws (Ø 4x12 mm are needed to mount the SSR on the heatsink.
5.
For optimal thermal performance heatsink fins should be oriented vertically
to promote the perfect convection airflow.
MOUNTING ON PANEL
1.
Before mounting the SSR, locate the panel
section. The surface must provide adequate
heat sinking capability - preferably aluminum,
uncoated, flat and clean.
2.
Recommended to use a thermal pad or thermal
grease between the SSR and the panel.
3.
SSR mounting slots have a diameter of 4.7 mm.
Please use two screws to mount on the panel.
4.
Be sure to tighten both screws until they
contact the baseplate before
applying full torque (1.2 Nm).
For more information please go to www.crouzet.com
SSR - PANEL MOUNT
DUAL CHANNEL
Panel mount - AC Output Dual Channel
• 25 and 50 Amps
• 2 independent SSRs in one package
• Zero-Voltage Turn-On and Instantaneous
(Random) Turn-On
!
2
• cRUus, CE and UKCA Recognized
PART NUMBER NOMENCLATURE
Output
Channels
Current
84140
0
84140:
0:
25 A
GN2
Dual
6:
50 A
Channel
25 A |
8:
Fast-on
CONNECTION
OUTPUT WIRING
NUMBER OF WIRES -
Direct connection with wires with or without ferrules
1
SOLID
STRANDED
(No ferrule)
(With ferrule)
1.5..10 mm²
1.5..6 mm²
AWG16..AWG8
AWG16..AWG10
INPUT WIRING
NUMBER OF WIRES -
Direct connection with wires with or without ferrules
1
SOLID
STRANDED
(No ferrule)
(With ferrule)
0.2..2.5 mm²
0.2..2.5 mm²
AWG26..AWG12
AWG26..AWG12
SCREWDRIVER TYPE:
POZIDRIV 2
!
WARNING:
The user should protect heat sensitive materials as well as people
against any contact with the heatsink. For correct cooling, the SSR needs air convection.
Less air convection produces an abnormal heating. In the event there is no space
between two SSRs, reduce the load current. Forced cooling (ex. fan inside the cabinet)
significantly improves the thermal performance. Heatsink temperature should never
exceed 90 °C.
INSTALLATION SHEET
C.MC.DEF.00888.EN
Control
Voltage
Connectivity
1
0
0:
4-32 V
|
0:
Fast-on | Zero Cross
c
Zero Cross
Screws | Instantaneous
1:
1:
10-30 V
|
c
3:
Screws | Zero Cross
Zero Cross
10-30 V
|
3:
c
Instantaneous
2
Recommended
SOLID
STRANDED
(No ferrule)
(With ferrule)
M5 screw N.m
Min 2 / Typ 2.4
1.5..10 mm²
1.5..6 mm²
AWG16..AWG8
AWG16..AWG10
Recommended
Generation
N
N:
New
Tightening
Torque
/ Max 3
Tightening
Torque
Min 0.4 /
Max 0.5