Relay output (12 V) - Auxiliary heat
The relay activation logic depends on whether the air to water unit is configured to work with
supply water temperature or room temperature. No additional configuration is required in the
Aidoo.
EN
Aerothermal LWT mode
Circuit status
Circuit 1 y Circuit 2 OFF
Circuit 1 and/or Circuit 2 ON
Circuit 1 and/or Circuit 2 on
demand
DHW ON
DHW OFF
Aidoo Pro air to water units can work with up to 2 zones and DHW depending on the
characteristics of each air to water unit. If there is more than one zone, they must all have the
same working settings.
Diagnostic LEDs
6
Relay
OFF
ON
ON
OFF
OFF
Connecting to a Wi-Fi network
Connected to a Wi-Fi network
Connected to the server
Not configured
Cloud Communications
Microprocessor activity
Power supply
Transmission of data to the indoor unit
Reception of data from the indoor unit
Aerothermal TH mode
Circuit status
Circuit 1 y Circuit 2 OFF
Circuit 1 and/or Circuit 2 ON
Circuit 1 and/or Circuit 2 on
demand
DHW ON
DHW OFF
Meaning
Blinking
Steady
Steady
Off
Blinking
Blinking
Steady
Blinking
Blinking
Relay
OFF
OFF
ON
OFF
OFF
Green
Blue
-
Red
Green
Red
Red
Green