9. Tighten the thrust bearing locking screw.
Guide pin adjustment
1. Loosen screws.
2. Press guide pins together, keep 0.5 mm distance between guide pin and the saw blade.
3. Tighten screws again.
4. Attach the working table to the table trunnion.
5. Fit the U shape under block to the working table.
3.5.6.
Table Insert Replacement